Study of pH sensors based on TiO2 nanotubes

G. Z. Monteiro, P. Marques, I. Pereyra, K. F. Albertin
{"title":"Study of pH sensors based on TiO2 nanotubes","authors":"G. Z. Monteiro, P. Marques, I. Pereyra, K. F. Albertin","doi":"10.1109/SBMICRO.2014.6940087","DOIUrl":null,"url":null,"abstract":"TiO2 nanotube arrays obtained by Ti foil anodization are tested as pH electrodes, showing performance close to standard glass electrodes. The TiO2 nanotube arrays were obtained by Ti foil anodization in a NH4F organic solution with 20, 40 and 60 V and different anodization times. The obtained nanotubes samples were characterized by Scanning Electron Microscopy (SEM). Electrode modified by TiO2 nanotubes were characterized in pH buffer solution (pH of 4.0, 7.0 and 10.0) and the obtained results show that electrode modified by NTs obtained with anodization voltage of 40 V with 45 minutes presents an almost linear response close to Nernst equation (59 mV/pH).","PeriodicalId":244987,"journal":{"name":"2014 29th Symposium on Microelectronics Technology and Devices (SBMicro)","volume":"58 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 29th Symposium on Microelectronics Technology and Devices (SBMicro)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SBMICRO.2014.6940087","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

TiO2 nanotube arrays obtained by Ti foil anodization are tested as pH electrodes, showing performance close to standard glass electrodes. The TiO2 nanotube arrays were obtained by Ti foil anodization in a NH4F organic solution with 20, 40 and 60 V and different anodization times. The obtained nanotubes samples were characterized by Scanning Electron Microscopy (SEM). Electrode modified by TiO2 nanotubes were characterized in pH buffer solution (pH of 4.0, 7.0 and 10.0) and the obtained results show that electrode modified by NTs obtained with anodization voltage of 40 V with 45 minutes presents an almost linear response close to Nernst equation (59 mV/pH).
基于TiO2纳米管的pH传感器研究
通过钛箔阳极氧化得到的TiO2纳米管阵列作为pH电极进行了测试,其性能接近标准玻璃电极。在NH4F有机溶液中,分别以20、40、60 V和不同阳极时间对Ti箔进行阳极氧化,得到了TiO2纳米管阵列。用扫描电子显微镜(SEM)对制备的纳米管样品进行了表征。在pH为4.0、7.0和10.0的缓冲溶液中对TiO2纳米管修饰的电极进行了表征,结果表明,在40 V、45分钟的阳极氧化电压下,纳米管修饰的电极具有接近于Nernst方程(59 mV/pH)的线性响应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信