Measuring uniaxial joint angles with a minimal accelerometer configuration

Wei Dong, I. Chen, Kwang Yong Lim, Y. K. Goh
{"title":"Measuring uniaxial joint angles with a minimal accelerometer configuration","authors":"Wei Dong, I. Chen, Kwang Yong Lim, Y. K. Goh","doi":"10.1145/1328491.1328515","DOIUrl":null,"url":null,"abstract":"This paper describes an approach to accurate measurement of human joint flexion-extension angles with four biaxial accelerometers. In this method, the absolute joint angle is calculated by comparing the readings of a pair of virtual accelerometers at the joint center of rotation. The simulation results show that the measurement has high accuracy compared to the reference system (correlation coefficient factor = 0.982). Given its portability, relative low cost and high accuracy proven by simulation results, the system can be applied to motion tracking for home-based rehabilitation.","PeriodicalId":241320,"journal":{"name":"International Convention on Rehabilitation Engineering & Assistive Technology","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Convention on Rehabilitation Engineering & Assistive Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/1328491.1328515","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

Abstract

This paper describes an approach to accurate measurement of human joint flexion-extension angles with four biaxial accelerometers. In this method, the absolute joint angle is calculated by comparing the readings of a pair of virtual accelerometers at the joint center of rotation. The simulation results show that the measurement has high accuracy compared to the reference system (correlation coefficient factor = 0.982). Given its portability, relative low cost and high accuracy proven by simulation results, the system can be applied to motion tracking for home-based rehabilitation.
用最小加速度计配置测量单轴关节角
本文介绍了一种用四个双轴加速度计精确测量人体关节屈伸角的方法。在该方法中,通过比较一对虚拟加速度计在关节旋转中心的读数来计算关节的绝对角度。仿真结果表明,与参考系统相比,测量精度较高(相关系数系数= 0.982)。仿真结果表明,该系统具有便携性好、成本相对较低、精度高的特点,可应用于居家康复的运动跟踪。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信