Evaluation of the effectiveness of anomalous systems in gas subsidiaries (Case study of Alborz Gas Company)

F. Ghasemi, Alireza Kazemian Talkhooncheh, M. R. Miri Lavasani
{"title":"Evaluation of the effectiveness of anomalous systems in gas subsidiaries (Case study of Alborz Gas Company)","authors":"F. Ghasemi, Alireza Kazemian Talkhooncheh, M. R. Miri Lavasani","doi":"10.7494/jge.2022.39.3.5025","DOIUrl":null,"url":null,"abstract":"An anomaly is an unsafe condition or action that has the potential to cause an accident. These conditions or unsafe practices in gas companies play a very important role in the occurrence of gas leaks and fires. Any unsafe acts can lead to unpleasant incidents for citizens and their homes and property. The aim of this study is to increase the effectiveness of anomalous systems in gas subsidiaries of Alborz province. To conduct this study, Tripod Beta technique to draw a diagram of analysis of gas accidents in homes in Alborz province and hierarchical analysis method was used to assess the risk of injuries, casualties and unintentional house fires. In the first stage, information on gas leaks and fires was collected by reviewing the documents related to the winter events of 2020. Then the sum of the mentioned conditions was studied as a hypothetical model. In the second step, the mentioned model was analyzed using Tripod Beta method and the causes of the accident were determined by the capability of the study method. The obstacles studied were technical safety regulations and the creation of a safe environment. The immediate reason attached to the technical safety regulations was the lack of proper understanding of the valve opening and closing sign. Another immediate reason for creating a safe environment was the lack of safe equipment. The precondition for not understanding the open and closed sign of the valve, lack of sufficient knowledge and the precondition for not using safe equipment, buying unsafe equipment and the hidden reason for lack of sufficient knowledge, lack of training and the hidden reason for buying unsafe equipment was poor economic situation. The results of this study indicated that fire-related conditions are of the utmost importance in assessing the risk of unintentional house fires. Failure to pay attention to safety points while using gas-related equipment, poor condition of the building and more male residents have the most anomalies in causing gas company accidents.","PeriodicalId":261652,"journal":{"name":"Journal of Geotechnology and Energy","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Geotechnology and Energy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7494/jge.2022.39.3.5025","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

An anomaly is an unsafe condition or action that has the potential to cause an accident. These conditions or unsafe practices in gas companies play a very important role in the occurrence of gas leaks and fires. Any unsafe acts can lead to unpleasant incidents for citizens and their homes and property. The aim of this study is to increase the effectiveness of anomalous systems in gas subsidiaries of Alborz province. To conduct this study, Tripod Beta technique to draw a diagram of analysis of gas accidents in homes in Alborz province and hierarchical analysis method was used to assess the risk of injuries, casualties and unintentional house fires. In the first stage, information on gas leaks and fires was collected by reviewing the documents related to the winter events of 2020. Then the sum of the mentioned conditions was studied as a hypothetical model. In the second step, the mentioned model was analyzed using Tripod Beta method and the causes of the accident were determined by the capability of the study method. The obstacles studied were technical safety regulations and the creation of a safe environment. The immediate reason attached to the technical safety regulations was the lack of proper understanding of the valve opening and closing sign. Another immediate reason for creating a safe environment was the lack of safe equipment. The precondition for not understanding the open and closed sign of the valve, lack of sufficient knowledge and the precondition for not using safe equipment, buying unsafe equipment and the hidden reason for lack of sufficient knowledge, lack of training and the hidden reason for buying unsafe equipment was poor economic situation. The results of this study indicated that fire-related conditions are of the utmost importance in assessing the risk of unintentional house fires. Failure to pay attention to safety points while using gas-related equipment, poor condition of the building and more male residents have the most anomalies in causing gas company accidents.
天然气子公司异常系统有效性评价(以Alborz天然气公司为例)
异常是有可能导致事故的不安全状况或行为。燃气公司的这些条件或不安全操作在燃气泄漏和火灾的发生中起着非常重要的作用。任何不安全的行为都可能对公民及其家庭和财产造成不愉快的事件。本研究的目的是提高阿尔博尔斯省天然气子公司异常系统的有效性。为了开展这项研究,我们采用了Tripod Beta技术绘制了阿尔布尔斯省家庭燃气事故分析图表,并采用层次分析法评估了伤害、伤亡和意外房屋火灾的风险。在第一阶段,通过审查与2020年冬季事件相关的文件,收集了有关天然气泄漏和火灾的信息。然后将上述条件的总和作为假设模型进行研究。第二步,使用Tripod Beta方法对上述模型进行分析,并根据研究方法的能力确定事故原因。所研究的障碍是技术安全条例和创造安全环境。附在技术安全法规上的直接原因是缺乏对阀门开启和关闭标志的正确理解。创造安全环境的另一个直接原因是缺乏安全设备。不了解阀门的启闭标志的前提条件、缺乏足够的知识和不使用安全设备的前提条件、购买不安全设备的隐藏原因和缺乏足够的知识、缺乏培训和购买不安全设备的隐藏原因是经济状况不佳。本研究结果表明,火灾相关条件是评估意外房屋火灾风险的最重要因素。煤气公司事故发生的异常因素主要是煤气设备使用时不注意安全、建筑物条件差、男性居多等。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信