Transistorized Vertical Scan System for Magnetic Deflection

Fuad L. Abboud
{"title":"Transistorized Vertical Scan System for Magnetic Deflection","authors":"Fuad L. Abboud","doi":"10.1109/TBTR2.1960.4503088","DOIUrl":null,"url":null,"abstract":"A transistorized vertical deflection system has been developed to scan a 90-degree, 14-inch picture tube at 14 KV accelerating voltage. This system consists of two transistors in a common-emitter multivibrator to form a vertical oscillator, one transistor as a driver and one output transistor, and the system is supplied power from a 12-volt d-c source. To prevent decentering of the raster, due to the d-c component of current in the deflection-coils, the output stage is coupled to these coils by means of an isolation transformer. Feedback networks are introduced to correct for the non-linear characteristics of the transistors, and to predistort the input waveform to the output transistor in order to compensate for the non-linearity of the transformer.","PeriodicalId":136909,"journal":{"name":"Ire Transactions on Broadcast and Television Receivers","volume":"45 5","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1960-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ire Transactions on Broadcast and Television Receivers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TBTR2.1960.4503088","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

A transistorized vertical deflection system has been developed to scan a 90-degree, 14-inch picture tube at 14 KV accelerating voltage. This system consists of two transistors in a common-emitter multivibrator to form a vertical oscillator, one transistor as a driver and one output transistor, and the system is supplied power from a 12-volt d-c source. To prevent decentering of the raster, due to the d-c component of current in the deflection-coils, the output stage is coupled to these coils by means of an isolation transformer. Feedback networks are introduced to correct for the non-linear characteristics of the transistors, and to predistort the input waveform to the output transistor in order to compensate for the non-linearity of the transformer.
磁偏转的晶体管垂直扫描系统
研制了一种晶体管垂直偏转系统,用于在14千伏加速电压下扫描90度14英寸显像管。该系统由一个共发射极多振子中的两个晶体管构成垂直振荡器,一个晶体管作为驱动晶体管和一个输出晶体管,系统由一个12伏直流电源供电。为了防止栅格的偏心,由于偏转线圈中电流的直流分量,输出级通过隔离变压器与这些线圈耦合。引入反馈网络来校正晶体管的非线性特性,并对输出晶体管的输入波形进行预失真,以补偿变压器的非线性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信