Streak Camera Observations of Partial Discharg Polyethylene under Fast Impulse Voltage Stress

J. Parpal
{"title":"Streak Camera Observations of Partial Discharg Polyethylene under Fast Impulse Voltage Stress","authors":"J. Parpal","doi":"10.1109/CEIDP.1991.763381","DOIUrl":null,"url":null,"abstract":"Samples of polyethylene with electrical trees at the tip of a needle radius/9 mm gap) molded into the material were subjected to voltage impulses of between 50 and 85 kV (20 ns/2 /spl mu/s). The light emitted from the partial discharges was recorded with a streak camera. Light was emitted for less than 20 ns for a positive impulse of 70 kV. The recorded light was located in the region of the electrical tree and the \"length\" of the recorded light increased with the growth of the tree. There was degradation of the emitting region after many impulses, except in one branch. The rate of growth of the electrical tree leading to final breakdown depends also on the mechanical stress applied sample.","PeriodicalId":277387,"journal":{"name":"1991 Annual Report. Conference on Electrical Insulation and Dielectric Phenomena,","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1991-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1991 Annual Report. Conference on Electrical Insulation and Dielectric Phenomena,","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.1991.763381","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Samples of polyethylene with electrical trees at the tip of a needle radius/9 mm gap) molded into the material were subjected to voltage impulses of between 50 and 85 kV (20 ns/2 /spl mu/s). The light emitted from the partial discharges was recorded with a streak camera. Light was emitted for less than 20 ns for a positive impulse of 70 kV. The recorded light was located in the region of the electrical tree and the "length" of the recorded light increased with the growth of the tree. There was degradation of the emitting region after many impulses, except in one branch. The rate of growth of the electrical tree leading to final breakdown depends also on the mechanical stress applied sample.
快速脉冲电压应力下局部放电聚乙烯的条纹相机观察
在针尖半径(9毫米间隙)处模塑的聚乙烯样品中,施加50至85千伏(20 ns/2 /spl mu/s)的电压脉冲。局部放电发出的光用条纹照相机记录了下来。在70千伏的正脉冲下,光的发射时间不到20毫秒。记录光位于电树的区域,记录光的“长度”随着树的生长而增加。除一个支路外,在多次脉冲后发射区有退化现象。导致最终击穿的电树的生长速率也取决于施加在样品上的机械应力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信