{"title":"Control of a three-phase four-wire shunt-active power filter based on DC-bus energy regulation","authors":"P. Rodríguez, A. Luna, R. Teodorescu, F. Blaabjerg, Marco Liserre","doi":"10.1109/OPTIM.2008.4602371","DOIUrl":null,"url":null,"abstract":"This paper presents a nonconventional three-phase four-wire shunt active power filter (APF) topology controlled by using an energy approach. A general study of power terms involved in the operation of the four-wire APF is conducted in order to evidence the relationship between instantaneous energy stored in the DC bus and active power requirements on the APF. Harmonics and imbalances both on the utility voltage and load current have been considered and the power developed by the active power filter has been evaluated. This study allows designing a controller for the APF based on the regulation of the energy-state of its DC-bus. The method has been experimentally tested on a four leg APF based on a neutral-point-clamped DC bus. Such topology allowed the test of the most general case, including harmonics and imbalance in utility voltage and in load currents.","PeriodicalId":244464,"journal":{"name":"2008 11th International Conference on Optimization of Electrical and Electronic Equipment","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2008-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 11th International Conference on Optimization of Electrical and Electronic Equipment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/OPTIM.2008.4602371","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

This paper presents a nonconventional three-phase four-wire shunt active power filter (APF) topology controlled by using an energy approach. A general study of power terms involved in the operation of the four-wire APF is conducted in order to evidence the relationship between instantaneous energy stored in the DC bus and active power requirements on the APF. Harmonics and imbalances both on the utility voltage and load current have been considered and the power developed by the active power filter has been evaluated. This study allows designing a controller for the APF based on the regulation of the energy-state of its DC-bus. The method has been experimentally tested on a four leg APF based on a neutral-point-clamped DC bus. Such topology allowed the test of the most general case, including harmonics and imbalance in utility voltage and in load currents.
基于直流母线能量调节的三相四线并联有源电力滤波器控制
本文提出了一种采用能量控制的非常规三相四线并联有源电力滤波器拓扑结构。为了证明直流母线中存储的瞬时能量与APF上的有功功率需求之间的关系,对四线制APF运行中涉及的功率术语进行了一般研究。考虑了电力电压和负载电流的谐波和不平衡,并对有源电力滤波器产生的功率进行了评价。本研究允许设计一个基于直流母线能量状态调节的有源滤波器控制器。该方法已在基于中性点箝位直流母线的四支路有源滤波器上进行了实验测试。这种拓扑结构允许测试最一般的情况,包括谐波和不平衡的公用事业电压和负载电流。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信