Protection of electronic equipment inside buildings: A hidden source of damages

A. Panicali, J. Pissolato Filho, C. Barbosa, J. C. O. Silva, N. V. B. Alves
{"title":"Protection of electronic equipment inside buildings: A hidden source of damages","authors":"A. Panicali, J. Pissolato Filho, C. Barbosa, J. C. O. Silva, N. V. B. Alves","doi":"10.1109/ICLP.2016.7791488","DOIUrl":null,"url":null,"abstract":"This paper shows that the criteria for the installation of surge protective devices (SPD) in power distribution panels as prescribed in standards on lightning protection and on low-voltage electrical installations may not prevent damages of sensitive electronic equipment, regardless of the protection level of the SPD and ground impedance. This is due to a not so evident source of damages related to incidental flashovers occurring between the equipment frame and grounded structures such as the floor underneath. This paper investigates this issue from experimental and theoretical approaches and provides some procedures in order to avoid such type of damages.","PeriodicalId":373744,"journal":{"name":"2016 33rd International Conference on Lightning Protection (ICLP)","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 33rd International Conference on Lightning Protection (ICLP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICLP.2016.7791488","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

This paper shows that the criteria for the installation of surge protective devices (SPD) in power distribution panels as prescribed in standards on lightning protection and on low-voltage electrical installations may not prevent damages of sensitive electronic equipment, regardless of the protection level of the SPD and ground impedance. This is due to a not so evident source of damages related to incidental flashovers occurring between the equipment frame and grounded structures such as the floor underneath. This paper investigates this issue from experimental and theoretical approaches and provides some procedures in order to avoid such type of damages.
建筑物内电子设备的保护:一个潜在的损害来源
本文认为,雷电防护标准和低压电气装置标准中配电板防雷装置的安装标准,无论防雷装置的保护等级和接地阻抗如何,都不能防止敏感电子设备的损坏。这是由于与设备框架和接地结构(如下面的地板)之间发生的偶然闪络有关的损害来源不那么明显。本文从实验和理论两方面对这一问题进行了探讨,并提出了避免此类损害的一些步骤。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信