Evaluasi Kualitas Citra Mamografi Metode Automatic Exposure Control (AEC) Menggunakan Normalized Anisotropic Quality Index (NAQI)

R. Anggraini, Ni Larasati Kartika Sari, I. Kusuma, Febria Anita
{"title":"Evaluasi Kualitas Citra Mamografi Metode Automatic Exposure Control (AEC) Menggunakan Normalized Anisotropic Quality Index (NAQI)","authors":"R. Anggraini, Ni Larasati Kartika Sari, I. Kusuma, Febria Anita","doi":"10.47313/jig.v25i2.1651","DOIUrl":null,"url":null,"abstract":". Mammography image is expected to have high image resolution quality so that the image is able to show microcalcifications as a sign of a malignant breast tumor with a size ranging from 0.1 mm . Automatic Exposure Control (AEC) is an image acquisition mode in mammography that is designed to strike a balance between patient dose and image quality by accommodating differences in breast size. This study aims to obtain the results of measuring mammographic image quality using Normalized Anisotropic Quality Index (NAQI), assessing the performance of AEC against variations in Compressed Breast Thicknes ( CBT), density and Average Glandular Dose (AGD). This study using 20 mammographic images in AEC mode, Cranio Caudal (CC) projections. The data in the forms of CBT, breast density and AGD were also taken. In this study, the CBT range was 45-81 mm, the density range was 14-18%, the AGD range was 1.25-2.26 mGy with the patient's age ranged from 39-67 years and the compression pressure ranged from 20.0169-157.9111 N. Then the images are grouped based on CBT, density and AGD, to get the NAQI values. The results of NAQI values are e ues sults o (0.111-2) . The highest NAQI value obtained on CBT images of 61 mm, density 14.64% and AGD 1.41 mGy .","PeriodicalId":389584,"journal":{"name":"Jurnal Ilmiah Giga","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Ilmiah Giga","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47313/jig.v25i2.1651","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

. Mammography image is expected to have high image resolution quality so that the image is able to show microcalcifications as a sign of a malignant breast tumor with a size ranging from 0.1 mm . Automatic Exposure Control (AEC) is an image acquisition mode in mammography that is designed to strike a balance between patient dose and image quality by accommodating differences in breast size. This study aims to obtain the results of measuring mammographic image quality using Normalized Anisotropic Quality Index (NAQI), assessing the performance of AEC against variations in Compressed Breast Thicknes ( CBT), density and Average Glandular Dose (AGD). This study using 20 mammographic images in AEC mode, Cranio Caudal (CC) projections. The data in the forms of CBT, breast density and AGD were also taken. In this study, the CBT range was 45-81 mm, the density range was 14-18%, the AGD range was 1.25-2.26 mGy with the patient's age ranged from 39-67 years and the compression pressure ranged from 20.0169-157.9111 N. Then the images are grouped based on CBT, density and AGD, to get the NAQI values. The results of NAQI values are e ues sults o (0.111-2) . The highest NAQI value obtained on CBT images of 61 mm, density 14.64% and AGD 1.41 mGy .
。乳房x线摄影图像应具有较高的图像分辨率,以便图像能够显示微钙化,这是乳房恶性肿瘤的标志,大小在0.1 mm左右。自动曝光控制(AEC)是乳房x线摄影中的一种图像采集模式,旨在通过适应乳房大小的差异,在患者剂量和图像质量之间取得平衡。本研究旨在获得使用归一化各向异性质量指数(NAQI)测量乳房x线图像质量的结果,评估AEC对压缩乳房厚度(CBT),密度和平均腺体剂量(AGD)变化的性能。本研究使用20张AEC模式乳房x线摄影图像,颅尾部(CC)投影。同时采集CBT、乳腺密度、AGD等数据。在本研究中,CBT范围为45 ~ 81 mm,密度范围为14 ~ 18%,AGD范围为1.25 ~ 2.26 mGy,患者年龄范围为39 ~ 67岁,压迫压力范围为20.0169 ~ 157.9111 n。然后根据CBT、密度、AGD对图像进行分组,得到NAQI值。NAQI值与(0.111-2)结果一致。在CBT图像61 mm,密度14.64%,AGD 1.41 mGy时,NAQI值最高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信