{"title":"Mixed-Mode S-Parameter Measurements for Determination of Cable Coupling","authors":"J. L. Rotgerink, N. Moonen, F. Leferink","doi":"10.23919/AeroEMC.2019.8788948","DOIUrl":null,"url":null,"abstract":"Single-ended S-parameters are used to quantify electromagnetic coupling, or crosstalk, between cables. The use of this measurement technique is demonstrated on a case where crosstalk occurs between two wire pairs above ground. S-parameter measurements involve no elements that introduce frequency restrictions, such as baluns or current clamps. Moreover, by measuring or simulating all combinations of S-parameters and converting these to mixed-mode S-parameters, not only differential-mode (DM), but also common-mode (CM) and mode-conversion S-parameters are obtained. When only the coupling between a specific combination of cables is desired, it is sufficient to measure only a small subset of all S-parameters. Finally, the relation between crosstalk as defined in the standards and the obtained S-parameters is discussed.","PeriodicalId":436679,"journal":{"name":"2019 ESA Workshop on Aerospace EMC (Aerospace EMC)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-08-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 ESA Workshop on Aerospace EMC (Aerospace EMC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/AeroEMC.2019.8788948","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
Single-ended S-parameters are used to quantify electromagnetic coupling, or crosstalk, between cables. The use of this measurement technique is demonstrated on a case where crosstalk occurs between two wire pairs above ground. S-parameter measurements involve no elements that introduce frequency restrictions, such as baluns or current clamps. Moreover, by measuring or simulating all combinations of S-parameters and converting these to mixed-mode S-parameters, not only differential-mode (DM), but also common-mode (CM) and mode-conversion S-parameters are obtained. When only the coupling between a specific combination of cables is desired, it is sufficient to measure only a small subset of all S-parameters. Finally, the relation between crosstalk as defined in the standards and the obtained S-parameters is discussed.