[The measurement of extravascular lung water--significant in the follow-up of ARDS?].

M Knoch, H Vogell, W Höltermann, E Müller, H Lennartz
{"title":"[The measurement of extravascular lung water--significant in the follow-up of ARDS?].","authors":"M Knoch,&nbsp;H Vogell,&nbsp;W Höltermann,&nbsp;E Müller,&nbsp;H Lennartz","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>In 40 adult patients suffering from severe ARDS stage III and IV (Morel) we examined the course of the extravascular lung water (EVLW) measured by the double indicator dilution method with 858 single measurements, during mechanical ventilation with PEEP, or extracorporeal CO2 elimination (ECCO2 R). No correlation could be found between EVLW and the values of alveolar arterial oxygen difference (AaDO2) and intrapulmonary right-left shunt (Qs/Qt) or haemodynamic values such as CVP, PCWP, mean pulmonary arterial pressure, or the 24 h fluid balance. It was, therefore, not possible to estimate a prognostic trend based on a single measurement of EVLW. However, the course EVLW was more appropriate to perceive the prognostic trend of ARDS because a rapid decrease of very high EVLW was correlated with a decrease of AaDO2 (r = 0.87); whereas lethal ARDS (fibrosis) was associated with moderately increased, unchanged EVLW. However, during the ECCO2-R treatment the repeated estimation of EVLW and AaDO2 is a useful tool to assess recovery because other parameters such as Qs/Qt and chest computer tomography during long-term bypass are very difficult or impossible to employ for this purpose. A change of EVLW with increasing PEEP level could not be found. The reproducibility of 858 EVLW values was excellent with a coefficient of variation of 4.9 +/- 3.5%.</p>","PeriodicalId":7813,"journal":{"name":"Anasthesie, Intensivtherapie, Notfallmedizin","volume":"25 6","pages":"411-5"},"PeriodicalIF":0.0000,"publicationDate":"1990-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anasthesie, Intensivtherapie, Notfallmedizin","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In 40 adult patients suffering from severe ARDS stage III and IV (Morel) we examined the course of the extravascular lung water (EVLW) measured by the double indicator dilution method with 858 single measurements, during mechanical ventilation with PEEP, or extracorporeal CO2 elimination (ECCO2 R). No correlation could be found between EVLW and the values of alveolar arterial oxygen difference (AaDO2) and intrapulmonary right-left shunt (Qs/Qt) or haemodynamic values such as CVP, PCWP, mean pulmonary arterial pressure, or the 24 h fluid balance. It was, therefore, not possible to estimate a prognostic trend based on a single measurement of EVLW. However, the course EVLW was more appropriate to perceive the prognostic trend of ARDS because a rapid decrease of very high EVLW was correlated with a decrease of AaDO2 (r = 0.87); whereas lethal ARDS (fibrosis) was associated with moderately increased, unchanged EVLW. However, during the ECCO2-R treatment the repeated estimation of EVLW and AaDO2 is a useful tool to assess recovery because other parameters such as Qs/Qt and chest computer tomography during long-term bypass are very difficult or impossible to employ for this purpose. A change of EVLW with increasing PEEP level could not be found. The reproducibility of 858 EVLW values was excellent with a coefficient of variation of 4.9 +/- 3.5%.

肺血管外水的测定——在ARDS随访中的重要意义?
我们对40例严重ARDS III期和IV期(Morel)的成人患者进行了858次单次测量,双指标稀释法测量血管外肺水(EVLW)的过程,在机械通气时,PEEP或体外CO2消除(ECCO2 R), EVLW与肺泡动脉氧差(AaDO2)和肺内左右分流(Qs/Qt)或血流动力学值如CVP, PCWP,平均肺动脉压,或24小时体液平衡。因此,不可能根据EVLW的单一测量来估计预测趋势。然而,病程EVLW更适合判断ARDS的预后趋势,因为EVLW的快速降低与AaDO2的降低相关(r = 0.87);而致死性ARDS(纤维化)与EVLW中度升高、不变相关。然而,在ECCO2-R治疗期间,EVLW和AaDO2的重复估计是评估恢复的有用工具,因为其他参数(如Qs/Qt和长期旁路期间的胸部计算机ct)很难或不可能用于此目的。EVLW未见随PEEP升高而变化。858个EVLW值的重复性好,变异系数为4.9 +/- 3.5%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信