Measurement of glucose levels with Quartz Crystal Microbalance (QCM) based sensor

Evin Şahi̇n Sadik, Hamdi Melih Saraoglu, M. A. Ebeoglu, İ. GÜrol, F. E. Kocak
{"title":"Measurement of glucose levels with Quartz Crystal Microbalance (QCM) based sensor","authors":"Evin Şahi̇n Sadik, Hamdi Melih Saraoglu, M. A. Ebeoglu, İ. GÜrol, F. E. Kocak","doi":"10.1109/TIPTEKNO.2016.7863100","DOIUrl":null,"url":null,"abstract":"Sensing and measurement methods with Quartz Crystal Microbalance (QCM) based sensors draw attention as an improving application among studies in recent years. This study is carried out for to be basis of studies on glucose level measurement using human blood serum using QCM sensors. In this paper, measurements with QCM sensor system using pure water containing several levels of glucose samples are carried out. Measurement results are analyzed with plots. The obtained results show that QCM based sensors are sensitive, repeatable and reliable sensor applications for blood glucose measurements.","PeriodicalId":431660,"journal":{"name":"2016 Medical Technologies National Congress (TIPTEKNO)","volume":"91 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 Medical Technologies National Congress (TIPTEKNO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TIPTEKNO.2016.7863100","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Sensing and measurement methods with Quartz Crystal Microbalance (QCM) based sensors draw attention as an improving application among studies in recent years. This study is carried out for to be basis of studies on glucose level measurement using human blood serum using QCM sensors. In this paper, measurements with QCM sensor system using pure water containing several levels of glucose samples are carried out. Measurement results are analyzed with plots. The obtained results show that QCM based sensors are sensitive, repeatable and reliable sensor applications for blood glucose measurements.
测量葡萄糖水平与石英晶体微天平(QCM)为基础的传感器
基于石英晶体微平衡(QCM)传感器的传感和测量方法是近年来研究中备受关注的一种改进应用。本研究的目的是为利用QCM传感器测量人血清葡萄糖水平的研究奠定基础。在本文中,用QCM传感器系统测量含有不同水平葡萄糖样品的纯水。用图对测量结果进行了分析。结果表明,基于QCM的传感器是一种灵敏、可重复、可靠的血糖测量传感器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信