Geophysical Case Study of the Gallen Deposit, Québec, Canada

Lizhen Cheng, Richard S. Smith, M. Allard, M. Chouteau, P. Keating, J. Lemieux, Marc A. Vallée, D. Bois, D. Fountain
{"title":"Geophysical Case Study of the Gallen Deposit, Québec, Canada","authors":"Lizhen Cheng, Richard S. Smith, M. Allard, M. Chouteau, P. Keating, J. Lemieux, Marc A. Vallée, D. Bois, D. Fountain","doi":"10.2113/GSEMG.16.1-2.67","DOIUrl":null,"url":null,"abstract":"As part of a larger research program, a number of MEGATEM airborne electromagnetic (EM) test flights were flown over the Gallen massive sulfide deposit in northwest Quebec. A particularity of this test site is that a major part of the ore body was extracted before the MEGATEM survey. Therefore one of the purposes of this study was to verify the ability of the system to detect the remaining massive sulfides below the water in the open pit. The open pit is also surrounded by a metallic fence, and a power line is present in the vicinity. A large part of the case study involved accounting for the impact of infrastructure and acidic water on the survey, which will help in the interpretation of airborne EM responses in complex exploration situations.\n\nThe Gallen deposit was also previously flown with the INPUT and GEOTEM airborne EM systems before the major exploitation period. A comparison between the results from the different survey results allows estimation of the physical properties of the Gallen deposit, which is a relatively poor conductor.\n\nA new method for removing the power line signal shows amplitudes with a smaller residual associated with the emanating fields, and more compact, cleaner responses associated with induced currents. This will make it easier to identify bedrock conductors close to power lines.","PeriodicalId":206160,"journal":{"name":"Exploration and Mining Geology","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Exploration and Mining Geology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2113/GSEMG.16.1-2.67","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

As part of a larger research program, a number of MEGATEM airborne electromagnetic (EM) test flights were flown over the Gallen massive sulfide deposit in northwest Quebec. A particularity of this test site is that a major part of the ore body was extracted before the MEGATEM survey. Therefore one of the purposes of this study was to verify the ability of the system to detect the remaining massive sulfides below the water in the open pit. The open pit is also surrounded by a metallic fence, and a power line is present in the vicinity. A large part of the case study involved accounting for the impact of infrastructure and acidic water on the survey, which will help in the interpretation of airborne EM responses in complex exploration situations. The Gallen deposit was also previously flown with the INPUT and GEOTEM airborne EM systems before the major exploitation period. A comparison between the results from the different survey results allows estimation of the physical properties of the Gallen deposit, which is a relatively poor conductor. A new method for removing the power line signal shows amplitudes with a smaller residual associated with the emanating fields, and more compact, cleaner responses associated with induced currents. This will make it easier to identify bedrock conductors close to power lines.
加拿大quamesbec galen矿床地球物理案例研究
作为一个大型研究项目的一部分,MEGATEM机载电磁(EM)测试飞行在魁北克西北部的Gallen块状硫化物矿床上空进行。该试验场的一个特点是,矿体的大部分是在MEGATEM调查之前提取的。因此,本研究的目的之一是验证该系统探测露天矿水中剩余块状硫化物的能力。露天矿也被金属栅栏包围,附近有一条输电线。案例研究的很大一部分涉及到基础设施和酸性水对调查的影响,这将有助于解释复杂勘探情况下的机载电磁响应。在主要开发阶段之前,Gallen矿床也曾使用INPUT和GEOTEM机载电磁系统进行过飞行。通过对不同测量结果的比较,可以对galen矿床的物理性质进行估计,该矿床的导体相对较差。一种消除电力线信号的新方法显示出与发射场相关的振幅与较小的残余,以及与感应电流相关的更紧凑,更清晰的响应。这将更容易识别靠近电力线的基岩导体。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信