Testing 144- and 256-crystal BGO block detectors

J. Rogers, R. Nutt, M. Andreaco, C. Williams
{"title":"Testing 144- and 256-crystal BGO block detectors","authors":"J. Rogers, R. Nutt, M. Andreaco, C. Williams","doi":"10.1109/NSSMIC.1993.373611","DOIUrl":null,"url":null,"abstract":"New block detectors have been fabricated incorporating large numbers of small crystals. The authors evaluate and compare the performance of the new detectors with a standard 64-crystal block detector from Siemens-CTI. The new detectors demonstrate greatly improved imaging capability for 511 keV gamma rays. Future PET tomographs incorporating such detectors should produce substantially better volume images with little increase in tomograph manufacturing costs. The detectors will require a new type of automatic calibration procedure. Various such procedures have been tested and are discussed. A technique using higher energy gamma rays has shown special promise.<<ETX>>","PeriodicalId":287813,"journal":{"name":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1993.373611","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 21

Abstract

New block detectors have been fabricated incorporating large numbers of small crystals. The authors evaluate and compare the performance of the new detectors with a standard 64-crystal block detector from Siemens-CTI. The new detectors demonstrate greatly improved imaging capability for 511 keV gamma rays. Future PET tomographs incorporating such detectors should produce substantially better volume images with little increase in tomograph manufacturing costs. The detectors will require a new type of automatic calibration procedure. Various such procedures have been tested and are discussed. A technique using higher energy gamma rays has shown special promise.<>
测试144和256晶体BGO块探测器
新的块探测器已经被制造出来,其中包含了大量的小晶体。作者将新探测器的性能与西门子- cti的标准64晶块探测器进行了评估和比较。新探测器对511kev伽马射线的成像能力有了很大的提高。未来的PET层析成像采用这种探测器将产生更好的体积图像,而层析成像制造成本几乎没有增加。这些探测器将需要一种新型的自动校准程序。各种这样的程序已经测试和讨论。一种利用高能伽马射线的技术显示出了特殊的前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信