Matched and mismatched pulse compression in medical ultrasound imaging

B.U. Zejak, I. Simic, A. Zejak
{"title":"Matched and mismatched pulse compression in medical ultrasound imaging","authors":"B.U. Zejak, I. Simic, A. Zejak","doi":"10.1109/EURCON.2001.938128","DOIUrl":null,"url":null,"abstract":"Pulse compression theory and techniques were developed originally for radar systems but could be carefully adopted for ultrasound-specific problems. In past ten years a considerable amount of research has been done in the area of mismatched filtering for the purpose of its application in ultrasound. However, in a similar way to radar systems for distributed targets, pulse compression has not achieved a success of penetration in commercially available systems.","PeriodicalId":205662,"journal":{"name":"EUROCON'2001. International Conference on Trends in Communications. Technical Program, Proceedings (Cat. No.01EX439)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"EUROCON'2001. International Conference on Trends in Communications. Technical Program, Proceedings (Cat. No.01EX439)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EURCON.2001.938128","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Pulse compression theory and techniques were developed originally for radar systems but could be carefully adopted for ultrasound-specific problems. In past ten years a considerable amount of research has been done in the area of mismatched filtering for the purpose of its application in ultrasound. However, in a similar way to radar systems for distributed targets, pulse compression has not achieved a success of penetration in commercially available systems.
医学超声成像中的匹配与不匹配脉冲压缩
脉冲压缩理论和技术最初是为雷达系统开发的,但可以谨慎地用于超声波特定问题。在过去的十年中,为了将非匹配滤波应用于超声,人们在该领域进行了大量的研究。然而,与用于分布式目标的雷达系统类似,脉冲压缩在商用系统中尚未取得穿透成功。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信