{"title":"Calibrated oscilloscopic system for RF time-domain characterization of non-linear devices","authors":"K. El-Akhdar, G. Neveux, D. Barataud, J. Nebus","doi":"10.1109/MMS.2013.6663103","DOIUrl":null,"url":null,"abstract":"This paper proposes a fully calibrated four channel high sampling rate oscilloscopic system based on the use of Track and Hold Amplifiers. The system achieves a high equivalent sampling rate (up to 1THz) using coherent interleaved sampling principle. An accurate calibration procedure allows a 10 kHz resolution over a 3 GHz bandwidth is applied. The capabilities of the system are presented and validated by characterizing a bandpass filter and an S-band 50 W GaN high power broadband amplifier under wideband CW pulsed signal excitation. S-parameters and power characteristics measurements are also presented. The fully calibrated system has the capability to give an accurate visualization of time-domain distortions of input/output voltage and current waveforms within the pulse. It also allows the determination of rising and falling transitions times of the pulse.","PeriodicalId":361750,"journal":{"name":"2013 13th Mediterranean Microwave Symposium (MMS)","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-11-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 13th Mediterranean Microwave Symposium (MMS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MMS.2013.6663103","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
This paper proposes a fully calibrated four channel high sampling rate oscilloscopic system based on the use of Track and Hold Amplifiers. The system achieves a high equivalent sampling rate (up to 1THz) using coherent interleaved sampling principle. An accurate calibration procedure allows a 10 kHz resolution over a 3 GHz bandwidth is applied. The capabilities of the system are presented and validated by characterizing a bandpass filter and an S-band 50 W GaN high power broadband amplifier under wideband CW pulsed signal excitation. S-parameters and power characteristics measurements are also presented. The fully calibrated system has the capability to give an accurate visualization of time-domain distortions of input/output voltage and current waveforms within the pulse. It also allows the determination of rising and falling transitions times of the pulse.