J. Paulino, Wallace Do C. Boaventura, Ivan Jose Da S. Lopes, Celio Fonseca Barbosa
{"title":"On the use of homogeneous ground model for lightning-induced voltage calculation","authors":"J. Paulino, Wallace Do C. Boaventura, Ivan Jose Da S. Lopes, Celio Fonseca Barbosa","doi":"10.1109/SIPDA.2015.7339308","DOIUrl":null,"url":null,"abstract":"Lightning induced voltages on aerial and underground lines depend on the ground resistivity. Most calculating methodologies were developed considering the ground as a homogeneous medium. However, actual ground is better represented if stratified into horizontal layers of different resistivity values. This paper proposes the use of a simplified expression for the calculation of the equivalent resistivity of a uniform ground that can represent a two-layer stratified ground in lightning induced voltage calculations. The analysis is made by comparing the results from a homogeneous ground having the equivalent resistivity value with results from two-layer ground. It is shown that, for the range of parameters considered, the absolute average and maximum errors on the induced voltage peak values are 2.9% and 8.2%, respectively. It is also shown that, with the equivalent resistivity, a peak-value formula developed for uniform ground could be used for the calculation of lightning induced voltages on lines above two-layer ground.","PeriodicalId":296478,"journal":{"name":"2015 International Symposium on Lightning Protection (XIII SIPDA)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Symposium on Lightning Protection (XIII SIPDA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIPDA.2015.7339308","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
Lightning induced voltages on aerial and underground lines depend on the ground resistivity. Most calculating methodologies were developed considering the ground as a homogeneous medium. However, actual ground is better represented if stratified into horizontal layers of different resistivity values. This paper proposes the use of a simplified expression for the calculation of the equivalent resistivity of a uniform ground that can represent a two-layer stratified ground in lightning induced voltage calculations. The analysis is made by comparing the results from a homogeneous ground having the equivalent resistivity value with results from two-layer ground. It is shown that, for the range of parameters considered, the absolute average and maximum errors on the induced voltage peak values are 2.9% and 8.2%, respectively. It is also shown that, with the equivalent resistivity, a peak-value formula developed for uniform ground could be used for the calculation of lightning induced voltages on lines above two-layer ground.