Performance analysis of a grid-connected PV system at Malaysian Energy Centre, Malaysia

R. A. Rahman, S. Sulaiman, A. M. Omar, S. Shaari, Z. Zain
{"title":"Performance analysis of a grid-connected PV system at Malaysian Energy Centre, Malaysia","authors":"R. A. Rahman, S. Sulaiman, A. M. Omar, S. Shaari, Z. Zain","doi":"10.1109/PEOCO.2010.5559155","DOIUrl":null,"url":null,"abstract":"This paper presents the performance of a 6.08 kWp grid-connected photovoltaic (PV) system installed at Malaysian Energy Centre (PTM), Bangi, Malaysia. The site is located at the latitude of approximately 2.96°N and longitude of 101.75°E. The system was commissioned on 14th June 2007 and the system performance has been monitored since 15th Jan 2008. The system comprises 6.08 kWp of PV array and a 4.6 kW inverter. An irradiance sensor and two temperature sensors are connected externally to the system via the inverter to obtain the irradiance, ambient temperature and module temperature profiles at the site. Apart from that, other performance data such as AC current AC voltage, DC current and DC voltage are recorded from the inverter. During the monitoring period, all data were recorded based on 15 minute interval. To date, the system had produced 17.205 MWh of solar electricity since commissioning.","PeriodicalId":379868,"journal":{"name":"2010 4th International Power Engineering and Optimization Conference (PEOCO)","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 4th International Power Engineering and Optimization Conference (PEOCO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEOCO.2010.5559155","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

This paper presents the performance of a 6.08 kWp grid-connected photovoltaic (PV) system installed at Malaysian Energy Centre (PTM), Bangi, Malaysia. The site is located at the latitude of approximately 2.96°N and longitude of 101.75°E. The system was commissioned on 14th June 2007 and the system performance has been monitored since 15th Jan 2008. The system comprises 6.08 kWp of PV array and a 4.6 kW inverter. An irradiance sensor and two temperature sensors are connected externally to the system via the inverter to obtain the irradiance, ambient temperature and module temperature profiles at the site. Apart from that, other performance data such as AC current AC voltage, DC current and DC voltage are recorded from the inverter. During the monitoring period, all data were recorded based on 15 minute interval. To date, the system had produced 17.205 MWh of solar electricity since commissioning.
马来西亚能源中心并网光伏系统的性能分析
本文介绍了安装在马来西亚邦宜的马来西亚能源中心(PTM)的6.08 kWp并网光伏(PV)系统的性能。该站点位于北纬约2.96°,东经101.75°。该系统于2007年6月14日投入使用,自2008年1月15日起开始监测系统性能。该系统包括6.08 kWp的光伏阵列和4.6 kW的逆变器。一个辐照度传感器和两个温度传感器通过逆变器外部连接到系统,以获得现场的辐照度、环境温度和模块温度曲线。除此之外,还记录了逆变器的其他性能数据,如交流电流、交流电压、直流电流和直流电压。监测期间,每隔15分钟记录一次所有数据。迄今为止,该系统自调试以来已产生17.205兆瓦时的太阳能电力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信