{"title":"COMPARATIVE ANALYSIS OF TOWER BASE TRANSCEIVER STATION (BTS) FOOT 4 BETWEEN BRACING TYPE V WITH BRACING TYPE X","authors":"CI-TECH Upnjatim, Sumaidi","doi":"10.33005/ci-tech.v1i01.10","DOIUrl":null,"url":null,"abstract":"\n \n \n \nThis paper explains the comparison 4-foot Base Transceiver Station (BTS) towers between type v bracing and type x bracing in terms of strength and economic aspects using SAP 2000 applications. As technology develops, people's desire for good telecommunications technology is enhancement. The writer analyzes the tower with type v bracing and type x bracing using the SAP 2000 application. BTS towers are used with a height of 25 meters, width of 6 meters, length of 6 meters, height of each segment of 2.5 meters. Then analyze the strengths using the SAP 2000 application based on the TIA / EIA 1991 standard with displacement not exceeding H/200. After the SAP 2000 application is finished running, the results of the building's own weight output are used for economic comparisons. The results of type v bracing analysis obtained a displacement of 0.4 millimeters with a building own weight of 123.668 KN. The result of type x bracing analysis obtained a displacement of 0.6 millimeters with a building weight of 143,440 KN. The results of this analysis recommend the BTS tower to use type v bracing instead of using type x bracing. \n \n \n \n","PeriodicalId":265863,"journal":{"name":"CI-TECH","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"CI-TECH","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33005/ci-tech.v1i01.10","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This paper explains the comparison 4-foot Base Transceiver Station (BTS) towers between type v bracing and type x bracing in terms of strength and economic aspects using SAP 2000 applications. As technology develops, people's desire for good telecommunications technology is enhancement. The writer analyzes the tower with type v bracing and type x bracing using the SAP 2000 application. BTS towers are used with a height of 25 meters, width of 6 meters, length of 6 meters, height of each segment of 2.5 meters. Then analyze the strengths using the SAP 2000 application based on the TIA / EIA 1991 standard with displacement not exceeding H/200. After the SAP 2000 application is finished running, the results of the building's own weight output are used for economic comparisons. The results of type v bracing analysis obtained a displacement of 0.4 millimeters with a building own weight of 123.668 KN. The result of type x bracing analysis obtained a displacement of 0.6 millimeters with a building weight of 143,440 KN. The results of this analysis recommend the BTS tower to use type v bracing instead of using type x bracing.