Ferrule Effect on Fracture Resistance of Endodontically Treated Teeth Restored With Two Esthetic Post and Core Materials Fabricated With Different Techniques

Mohamed W. Abdullah, Amina M. Hamdy, G. Abdelfattah
{"title":"Ferrule Effect on Fracture Resistance of Endodontically Treated Teeth Restored With Two Esthetic Post and Core Materials Fabricated With Different Techniques","authors":"Mohamed W. Abdullah, Amina M. Hamdy, G. Abdelfattah","doi":"10.21608/mjd.2023.301990","DOIUrl":null,"url":null,"abstract":": Objective: Assessment of ferrule effect on fracture resistance of Customized fiber post and Custom-made PEEK post with a core. Materials and Methods: Twenty eight single-rooted mandibular premolars with approximate similarity in shape and size and no cracks or caries were selected for this study. The length of the root was measured from the root apex to the middle point of the cementoenamel junction in the labial surface; it was about (16±1 mm). Teeth were divided into two groups, each group contained 14 teeth, with a ferrule group and without a ferrule group followed by coronal decapitation of all samples. Endodontic treatment was performed for all samples followed by mounting samples in acrylic blocks and then preparation of post space. Each group of the two groups was subdivided into two subgroups (n=7/subgroup), the first subgroup was restored with custom-made polyether ether ketone (PEEK) post and core, and the second subgroup was restored with customized fiber post and composite resin core. Results: Samples with ferrule (651.68±66.34) had a significantly higher fracture strength value than samples without ferrule (528.86±60.85) (p<0.001). Conclusions: based on the results and conditions of this study, the following findings can be drawn: With ferrule samples are more resistant to fracture than ferrule samples with the two different post types.","PeriodicalId":308616,"journal":{"name":"Mansoura Journal of Dentistry","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mansoura Journal of Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/mjd.2023.301990","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

: Objective: Assessment of ferrule effect on fracture resistance of Customized fiber post and Custom-made PEEK post with a core. Materials and Methods: Twenty eight single-rooted mandibular premolars with approximate similarity in shape and size and no cracks or caries were selected for this study. The length of the root was measured from the root apex to the middle point of the cementoenamel junction in the labial surface; it was about (16±1 mm). Teeth were divided into two groups, each group contained 14 teeth, with a ferrule group and without a ferrule group followed by coronal decapitation of all samples. Endodontic treatment was performed for all samples followed by mounting samples in acrylic blocks and then preparation of post space. Each group of the two groups was subdivided into two subgroups (n=7/subgroup), the first subgroup was restored with custom-made polyether ether ketone (PEEK) post and core, and the second subgroup was restored with customized fiber post and composite resin core. Results: Samples with ferrule (651.68±66.34) had a significantly higher fracture strength value than samples without ferrule (528.86±60.85) (p<0.001). Conclusions: based on the results and conditions of this study, the following findings can be drawn: With ferrule samples are more resistant to fracture than ferrule samples with the two different post types.
不同工艺制备的两种美观桩核材料对根管治疗后牙体抗折性能的影响
目的:评价卡套对定制纤维桩和定制带芯PEEK桩抗断裂性能的影响。材料与方法:选取28颗形状大小相近、无裂纹、无龋的单根下颌前磨牙作为研究对象。根的长度从根尖到牙髓-牙釉质交界的唇面中点测量;约为(16±1mm)。牙组分为两组,每组14颗牙,带卡箍组和不带卡箍组,全部标本冠状断头。对所有样品进行根管治疗,然后将样品安装在丙烯酸块中,然后准备桩位。两组每组再细分为2个亚组(n=7/亚组),第一亚组采用定制聚醚醚酮(PEEK)桩和核修复,第二亚组采用定制纤维桩和复合树脂核修复。结果:带卡箍试样的断裂强度值(651.68±66.34)显著高于未带卡箍试样的断裂强度值(528.86±60.85)(p<0.001)。结论:根据本研究的结果和条件,可以得出以下结论:带箍的样品比两种不同桩型带箍的样品更耐断裂。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信