Harmonic Source Identification Using Modified Power Direction Method

Pragya Joshi, S. K. Jain
{"title":"Harmonic Source Identification Using Modified Power Direction Method","authors":"Pragya Joshi, S. K. Jain","doi":"10.1109/RTEICT46194.2019.9016776","DOIUrl":null,"url":null,"abstract":"In this paper harmonic source identification has been done using active power direction method with the study of distortion caused by loads at the system nodes. The active power direction method is being continuously used until present date with required modifications and integration with other techniques in order to improve its application for the purpose of harmonic source detection. The effect of disturbing loads at the nodes renders significant information regarding the type of load connected to it. A comparative study of distorting and non-distorting portion of load parameters along with the power direction analysis is used as an effective tool to identify harmonic sources present in the system, better performance can be witnessed in this work on various test cases where power direction method fails. The effectiveness of the proposed technique has been tested on a modified IEEE 5 bus system and IEEE 9 bus system.","PeriodicalId":269385,"journal":{"name":"2019 4th International Conference on Recent Trends on Electronics, Information, Communication & Technology (RTEICT)","volume":"336 8","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 4th International Conference on Recent Trends on Electronics, Information, Communication & Technology (RTEICT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RTEICT46194.2019.9016776","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

In this paper harmonic source identification has been done using active power direction method with the study of distortion caused by loads at the system nodes. The active power direction method is being continuously used until present date with required modifications and integration with other techniques in order to improve its application for the purpose of harmonic source detection. The effect of disturbing loads at the nodes renders significant information regarding the type of load connected to it. A comparative study of distorting and non-distorting portion of load parameters along with the power direction analysis is used as an effective tool to identify harmonic sources present in the system, better performance can be witnessed in this work on various test cases where power direction method fails. The effectiveness of the proposed technique has been tested on a modified IEEE 5 bus system and IEEE 9 bus system.
基于修正功率方向法的谐波源识别
本文采用有源功率方向法进行谐波源识别,并研究了系统节点上负荷引起的畸变。有源功率方向法在谐波源检测中不断得到改进,并与其他技术相结合,以提高有源功率方向法的适用性。节点上干扰负载的影响提供了有关与其相连的负载类型的重要信息。将负载参数的畸变部分与非畸变部分进行对比研究,并结合功率方向分析作为识别系统中存在谐波源的有效工具,在功率方向法失效的各种测试用例中,本工作取得了较好的效果。在改进的ieee5总线系统和ieee9总线系统上测试了该技术的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信