Corneal Distortion and Corneal Morphological Parameters in Naïve Eyes Analyzed with a Scheimpflug Camera

Sandro Sbrodone, A. Ragucci, G. Iaccarino, Domenico de Robertis, Giovan Battista Scazzi, M. Lanza
{"title":"Corneal Distortion and Corneal Morphological Parameters in Naïve Eyes Analyzed with a Scheimpflug Camera","authors":"Sandro Sbrodone, A. Ragucci, G. Iaccarino, Domenico de Robertis, Giovan Battista Scazzi, M. Lanza","doi":"10.30560/mhs.v3n2p22","DOIUrl":null,"url":null,"abstract":"Background: The study of the corneal biomechanical properties (CBP) is gaining always more interest, thanks to the applications to refractive surgery and to the overall management of several corneal diseases. \nPurpose: To analyze the eventual relationships between corneal distortion and morphologic features in healthy subjects. \nMethods: one eye of one hundred and fifty-two healthy participants, 87 women and 65 men, aging from 23 to 65 years old, were evaluated in this study. Every eye underwent a complete clinical examination, that included also a tomographic scan using Pentacam HR (Oculus, Wetzlar, Germany) and a biomechanical evaluation using Corvis ST (Oculus, Wetzlar, Germany). Linear regressions among refractive defect, corneal volume (CV), anterior corneal curvature and central corneal thickness (CCT) vs corneal biomechanical features provided by Corvis ST have been ran using SPSS software version 18.0. \nResults: Corneal distortion factors showed a low correlation both with corneal morphological parameters and with refractive defect. No significant correlations (p> 0.01) were found among morphologic and biomechanical features evaluated. \nDiscussion: results observed in this study could help in recognize the healthy range of values of CBP parameters provided by CST. This information could be very useful in many ophthalmology topics such as the accurate IOP measurement, the early diagnosis of corneal degenerations, such as keratoconous, and the screening of subject undergoing refractive surgery. \nConclusions: even if data of this study need to be confirmed in further ones with larger populations, results here observed suggest that Corvis ST is a device providing an evaluation of corneal distortion not influenced by morphological corneal factors. This information could help in better screening and managing the diseased corneas.","PeriodicalId":421866,"journal":{"name":"Modern Health Science","volume":"292 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Modern Health Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30560/mhs.v3n2p22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The study of the corneal biomechanical properties (CBP) is gaining always more interest, thanks to the applications to refractive surgery and to the overall management of several corneal diseases. Purpose: To analyze the eventual relationships between corneal distortion and morphologic features in healthy subjects. Methods: one eye of one hundred and fifty-two healthy participants, 87 women and 65 men, aging from 23 to 65 years old, were evaluated in this study. Every eye underwent a complete clinical examination, that included also a tomographic scan using Pentacam HR (Oculus, Wetzlar, Germany) and a biomechanical evaluation using Corvis ST (Oculus, Wetzlar, Germany). Linear regressions among refractive defect, corneal volume (CV), anterior corneal curvature and central corneal thickness (CCT) vs corneal biomechanical features provided by Corvis ST have been ran using SPSS software version 18.0. Results: Corneal distortion factors showed a low correlation both with corneal morphological parameters and with refractive defect. No significant correlations (p> 0.01) were found among morphologic and biomechanical features evaluated. Discussion: results observed in this study could help in recognize the healthy range of values of CBP parameters provided by CST. This information could be very useful in many ophthalmology topics such as the accurate IOP measurement, the early diagnosis of corneal degenerations, such as keratoconous, and the screening of subject undergoing refractive surgery. Conclusions: even if data of this study need to be confirmed in further ones with larger populations, results here observed suggest that Corvis ST is a device providing an evaluation of corneal distortion not influenced by morphological corneal factors. This information could help in better screening and managing the diseased corneas.
用Scheimpflug相机分析Naïve眼的角膜畸变和角膜形态学参数
背景:由于角膜生物力学特性在屈光手术和多种角膜疾病的综合治疗中的应用,其研究越来越受到人们的关注。目的:分析健康受试者角膜畸变与角膜形态特征之间的最终关系。方法:对年龄在23 ~ 65岁之间的152名健康受试者(女性87人,男性65人)的一只眼睛进行评估。每只眼睛都进行了完整的临床检查,包括使用Pentacam HR (Oculus, Wetzlar, Germany)进行断层扫描,并使用Corvis ST (Oculus, Wetzlar, Germany)进行生物力学评估。利用SPSS 18.0软件对屈光缺损、角膜体积(CV)、角膜前曲率和角膜中央厚度(CCT)与Corvis ST提供的角膜生物力学特征进行线性回归。结果:角膜畸变因素与角膜形态参数及屈光性缺损均呈低相关性。形态学与生物力学指标间无显著相关性(p> 0.01)。讨论:本研究的结果有助于识别CST提供的CBP参数值的健康范围。这些信息在许多眼科课题中非常有用,如准确的IOP测量,角膜变性(如圆锥角膜)的早期诊断,以及接受屈光手术的受试者的筛选。结论:即使本研究的数据需要在更大人群的进一步研究中得到证实,这里观察到的结果表明,Corvis ST是一种不受角膜形态学因素影响的角膜畸变评估装置。这些信息有助于更好地筛查和治疗病变角膜。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信