Study the Topology Effect on a G3-PLC based AMI Network

Thobekile J. Ngcobo, Farzad Ghayoor
{"title":"Study the Topology Effect on a G3-PLC based AMI Network","authors":"Thobekile J. Ngcobo, Farzad Ghayoor","doi":"10.1109/ROBOMECH.2019.8704772","DOIUrl":null,"url":null,"abstract":"Smart grid is the concept for next-generation power grid that integrates information and communication technology into power grid. Advanced metering infrastructure (AMI) is an important aspect of smart grid, which requires establishment of a two-way communication system between consumers and utility. In this paper, the effect of network topology on the performance of a PLC-based AMI system is investigated. For this purpose, a narrow-band power line communication simulator in accordance with the G3-PLC standard is proposed that implemented using the OMNeT++ network simulator. It is shown that the topology of the AMI network has significant impact on the collision rate of the data concentrator switch.","PeriodicalId":344332,"journal":{"name":"2019 Southern African Universities Power Engineering Conference/Robotics and Mechatronics/Pattern Recognition Association of South Africa (SAUPEC/RobMech/PRASA)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 Southern African Universities Power Engineering Conference/Robotics and Mechatronics/Pattern Recognition Association of South Africa (SAUPEC/RobMech/PRASA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ROBOMECH.2019.8704772","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Smart grid is the concept for next-generation power grid that integrates information and communication technology into power grid. Advanced metering infrastructure (AMI) is an important aspect of smart grid, which requires establishment of a two-way communication system between consumers and utility. In this paper, the effect of network topology on the performance of a PLC-based AMI system is investigated. For this purpose, a narrow-band power line communication simulator in accordance with the G3-PLC standard is proposed that implemented using the OMNeT++ network simulator. It is shown that the topology of the AMI network has significant impact on the collision rate of the data concentrator switch.
基于G3-PLC的AMI网络拓扑效应研究
智能电网是将信息通信技术融入电网的下一代电网概念。高级计量基础设施(AMI)是智能电网的一个重要方面,它要求在用户和电力公司之间建立双向通信系统。本文研究了网络拓扑结构对基于plc的AMI系统性能的影响。为此,提出了一种符合G3-PLC标准的窄带电力线通信模拟器,并利用omnet++网络模拟器实现。研究表明,AMI网络的拓扑结构对数据集中器交换机的碰撞率有显著影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信