{"title":"Strength assessment of biomaterial models using selective sintering technology","authors":"P. Marchlewski","doi":"10.5604/01.3001.0013.3595","DOIUrl":null,"url":null,"abstract":"The article presents an innovative method for the assessment of mechanical properties of biomaterials. 3D models were used for this purpose, obtained by selective laser sintering, designed in various spatial configuration (size of pores, orientation of pores ). The Rotational Bridge test stand was used to carry out the tests, which allowed generating of twisting deformations in the tested materials. The values of the moment of torsion forces transferred by the tested models were analyzed and compared, depending on their spatial structure.\n\n","PeriodicalId":348539,"journal":{"name":"Inżynieria Powierzchni","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Inżynieria Powierzchni","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5604/01.3001.0013.3595","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The article presents an innovative method for the assessment of mechanical properties of biomaterials. 3D models were used for this purpose, obtained by selective laser sintering, designed in various spatial configuration (size of pores, orientation of pores ). The Rotational Bridge test stand was used to carry out the tests, which allowed generating of twisting deformations in the tested materials. The values of the moment of torsion forces transferred by the tested models were analyzed and compared, depending on their spatial structure.
利用选择性烧结技术对生物材料模型进行强度评估
本文提出了一种评价生物材料力学性能的创新方法。为此,使用了通过选择性激光烧结获得的三维模型,设计了各种空间配置(孔隙大小,孔隙取向)。采用旋转桥试验台进行试验,试验允许在被试材料中产生扭转变形。根据不同的空间结构,对模型传递的扭转力矩进行了分析和比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信