Symmetrical Components-Based Control Technique of Doubly Fed Induction Generators under Unbalanced Voltages for Reduction of Torque and Reactive Power Pulsations

S. Wangsathitwong, S. Sirisumrannukul, S. Chatratana, W. Deleroi
{"title":"Symmetrical Components-Based Control Technique of Doubly Fed Induction Generators under Unbalanced Voltages for Reduction of Torque and Reactive Power Pulsations","authors":"S. Wangsathitwong, S. Sirisumrannukul, S. Chatratana, W. Deleroi","doi":"10.1109/PEDS.2007.4487876","DOIUrl":null,"url":null,"abstract":"This paper presents a control technique to reduce the effect of unbalanced voltages in the doubly fed induction generator (DFIG) in wind energy conversion systems. The unbalanced voltages cause negative effects to the DFIG such as torque pulsation and increased stator current. Based on the symmetrical component theory, the negative sequence of the stator voltage can be extracted from the three-phase stator voltage and fed to compensate the rotor voltage to reduce the unbalanced effect. The magnitude of the compensating negative sequence is calculated from the negative sequence of the stator voltage and rotor speed. The proposed method shows a promising result for reduction of torque and reactive power pulsations.","PeriodicalId":166704,"journal":{"name":"2007 7th International Conference on Power Electronics and Drive Systems","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 7th International Conference on Power Electronics and Drive Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDS.2007.4487876","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

This paper presents a control technique to reduce the effect of unbalanced voltages in the doubly fed induction generator (DFIG) in wind energy conversion systems. The unbalanced voltages cause negative effects to the DFIG such as torque pulsation and increased stator current. Based on the symmetrical component theory, the negative sequence of the stator voltage can be extracted from the three-phase stator voltage and fed to compensate the rotor voltage to reduce the unbalanced effect. The magnitude of the compensating negative sequence is calculated from the negative sequence of the stator voltage and rotor speed. The proposed method shows a promising result for reduction of torque and reactive power pulsations.
基于对称分量的双馈异步发电机不平衡电压控制技术以减小转矩和无功脉动
本文提出了一种降低风力发电系统中双馈感应发电机(DFIG)电压不平衡影响的控制技术。电压不平衡会对DFIG产生转矩脉动和定子电流增大等负面影响。基于对称分量理论,从三相定子电压中提取出定子电压的负序并馈入补偿转子电压,以减小不平衡效应。补偿负序的大小由定子电压和转子转速的负序计算得到。该方法在减小转矩和无功脉动方面取得了良好的效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信