{"title":"Calculation and Analysis of Pollution Flashover Voltage of Porcelain Insulator in Transmission Line under Overheavy Pollution Environment","authors":"Xinwei Wang, Hua Yu, Hong Liu","doi":"10.1109/ITOEC53115.2022.9734516","DOIUrl":null,"url":null,"abstract":"Due to the shortage of transmission channels, individual transmission line towers inevitably need to pass through overheavy pollution environmental areas. The so-called overheavy polluted environment means that the SPS (site pollution severity) exceeds level-e. In the overheavy polluted environment, how to configure the insulation of transmission tower is a great test for the design, operation and maintenance of transmission line. Based on the above situation, through the existing test data, this paper predicts and calculates the flashover voltage($U$50%) of various types of disc suspension porcelain insulators; Through calculation, the external insulation configuration schemes under different ESDD (equivalent salt deposit density) are given to solve the pollution flashover problem of transmission lines in overheavy pollution environment.","PeriodicalId":127300,"journal":{"name":"2022 IEEE 6th Information Technology and Mechatronics Engineering Conference (ITOEC)","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE 6th Information Technology and Mechatronics Engineering Conference (ITOEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ITOEC53115.2022.9734516","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Due to the shortage of transmission channels, individual transmission line towers inevitably need to pass through overheavy pollution environmental areas. The so-called overheavy polluted environment means that the SPS (site pollution severity) exceeds level-e. In the overheavy polluted environment, how to configure the insulation of transmission tower is a great test for the design, operation and maintenance of transmission line. Based on the above situation, through the existing test data, this paper predicts and calculates the flashover voltage($U$50%) of various types of disc suspension porcelain insulators; Through calculation, the external insulation configuration schemes under different ESDD (equivalent salt deposit density) are given to solve the pollution flashover problem of transmission lines in overheavy pollution environment.