Mixed time-frame simulation

N. Watson, J. Arrillaga
{"title":"Mixed time-frame simulation","authors":"N. Watson, J. Arrillaga","doi":"10.1049/PBPO039E_ch12","DOIUrl":null,"url":null,"abstract":"The use of a single time frame throughout the simulation is inefficient for studies involving widely varying time constants. A typical example is multimachine transient stability assessment when the system contains HVDC converters. In such cases the stability levels are affected by both the long time constant of the electromechanical response of the generators and the short time constant of the converter's power electronic control. It is, of course, possible to include the equations of motion of the generators in the electromagnetic transient programs to represent the electromechanical behaviour of multimachine power systems. However, considering the different time constants influencing the electromechanical and electromagnetic behaviour, such approach would be extremely inefficient. Electromagnetic transient simulations use steps of (typically) 50 μs, whereas the stability programs use steps at least 200 times larger.","PeriodicalId":114635,"journal":{"name":"Power Systems Electromagnetic Transients Simulation","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Power Systems Electromagnetic Transients Simulation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1049/PBPO039E_ch12","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The use of a single time frame throughout the simulation is inefficient for studies involving widely varying time constants. A typical example is multimachine transient stability assessment when the system contains HVDC converters. In such cases the stability levels are affected by both the long time constant of the electromechanical response of the generators and the short time constant of the converter's power electronic control. It is, of course, possible to include the equations of motion of the generators in the electromagnetic transient programs to represent the electromechanical behaviour of multimachine power systems. However, considering the different time constants influencing the electromechanical and electromagnetic behaviour, such approach would be extremely inefficient. Electromagnetic transient simulations use steps of (typically) 50 μs, whereas the stability programs use steps at least 200 times larger.
混合时间框架模拟
在整个模拟过程中使用单一时间框架对于涉及广泛变化的时间常数的研究是低效的。一个典型的例子是含高压直流变流器的多机暂态稳定评估。在这种情况下,发电机机电响应的长时间常数和变流器电力电子控制的短时间常数同时影响稳定水平。当然,在电磁暂态程序中包含发电机的运动方程来表示多机电力系统的机电行为是可能的。然而,考虑到影响机电和电磁行为的不同时间常数,这种方法将是非常低效的。电磁瞬变模拟使用(通常)50 μs的步长,而稳定性程序使用至少200倍的步长。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信