Intelligent Management Design on Air Conditioning Nonlinear Group Load

Zhu Jian-hong, Meng Bang-bang, Gu Ju-ping, Hu Qiong, Chen Ze-yu
{"title":"Intelligent Management Design on Air Conditioning Nonlinear Group Load","authors":"Zhu Jian-hong, Meng Bang-bang, Gu Ju-ping, Hu Qiong, Chen Ze-yu","doi":"10.1109/AMCON.2018.8614851","DOIUrl":null,"url":null,"abstract":"Large-scale accessing to the power grid of non-linear load affects the power quality of the grid. The monitoring requirements of load electrical characteristics are more urgent with rapid increase in power energy demand. Aiming at the characteristics of non-linear group load operation of air conditioners, a systematic monitor project construction scheme is proposed. Firstly, the simulation software is used to build air-conditioning nonlinear group load model to observe characteristics and performance. Then, according to the energy characteristics of the nonlinear group load, the parameters and control variables, the data communication between the monitoring environment and the non-linear load operating simulation environment is designed, and the electrical characteristics of the nonlinear group load are monitored dynamically. Finally, the waveform analysis of the electrical characteristics is done and given the analysis result. Appropriating measures are taken to make the power quality meet the actual requirements, active power management is achieved in demand side.","PeriodicalId":438307,"journal":{"name":"2018 IEEE International Conference on Advanced Manufacturing (ICAM)","volume":"58 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE International Conference on Advanced Manufacturing (ICAM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AMCON.2018.8614851","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Large-scale accessing to the power grid of non-linear load affects the power quality of the grid. The monitoring requirements of load electrical characteristics are more urgent with rapid increase in power energy demand. Aiming at the characteristics of non-linear group load operation of air conditioners, a systematic monitor project construction scheme is proposed. Firstly, the simulation software is used to build air-conditioning nonlinear group load model to observe characteristics and performance. Then, according to the energy characteristics of the nonlinear group load, the parameters and control variables, the data communication between the monitoring environment and the non-linear load operating simulation environment is designed, and the electrical characteristics of the nonlinear group load are monitored dynamically. Finally, the waveform analysis of the electrical characteristics is done and given the analysis result. Appropriating measures are taken to make the power quality meet the actual requirements, active power management is achieved in demand side.
空调非线性群负荷智能管理设计
大规模接入电网的非线性负荷影响着电网的电能质量。随着电力能源需求的快速增长,对负荷电气特性的监测要求更加迫切。针对空调群负荷非线性运行的特点,提出了系统监控工程建设方案。首先,利用仿真软件建立空调非线性群负荷模型,观察其特性和性能。然后,根据非线性群负荷的能量特性、参数和控制变量,设计了监测环境与非线性负荷运行仿真环境之间的数据通信,实现了对非线性群负荷电气特性的动态监测。最后对其电特性进行了波形分析,并给出了分析结果。采取适当的措施使电能质量符合实际要求,实现了需求侧的有源电力管理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信