G. Brusco, A. Burgio, D. Menniti, M. Motta, A. Pinnarelli, N. Sorrentino
{"title":"A repetitive-based control for a single-phase shunt active power filter for harmonic voltage compensation","authors":"G. Brusco, A. Burgio, D. Menniti, M. Motta, A. Pinnarelli, N. Sorrentino","doi":"10.1109/EEEIC.2016.7555478","DOIUrl":null,"url":null,"abstract":"This paper is focused on a single phase shunt active filter based on detection of harmonic voltages at the point of installation; the mission of the active filter is to eliminate these harmonic voltages implementing a repetitive-based control. The active filter is a single-phase voltage-controlled voltage source inverter controlled so to generate a harmonic voltage in phase with the one detected at the point of installation. The proposed repetitive-based control regulates the power at the fundamental frequency so to maintaining the dc voltage of the capacitor placed on the dc side of the filter close to a reference; such an issue is faced implementing the self-charging functionality or supplying real power to the grid when the active filter is a distributed generation solution. Numerical results are provided so to demonstrate the effectiveness and the feasibility of the proposed repetitive-based control in compensating harmonic voltages in an electrical power distribution system.","PeriodicalId":246856,"journal":{"name":"2016 IEEE 16th International Conference on Environment and Electrical Engineering (EEEIC)","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 16th International Conference on Environment and Electrical Engineering (EEEIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEEIC.2016.7555478","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
This paper is focused on a single phase shunt active filter based on detection of harmonic voltages at the point of installation; the mission of the active filter is to eliminate these harmonic voltages implementing a repetitive-based control. The active filter is a single-phase voltage-controlled voltage source inverter controlled so to generate a harmonic voltage in phase with the one detected at the point of installation. The proposed repetitive-based control regulates the power at the fundamental frequency so to maintaining the dc voltage of the capacitor placed on the dc side of the filter close to a reference; such an issue is faced implementing the self-charging functionality or supplying real power to the grid when the active filter is a distributed generation solution. Numerical results are provided so to demonstrate the effectiveness and the feasibility of the proposed repetitive-based control in compensating harmonic voltages in an electrical power distribution system.