K. Mitsubayashi, Y. Miyoshi, T. Takeuchi, I. Karube
{"title":"Electric conductimetric sensor with a thin-layer structure for moisture analysis","authors":"K. Mitsubayashi, Y. Miyoshi, T. Takeuchi, I. Karube","doi":"10.1109/COMMAD.2002.1237231","DOIUrl":null,"url":null,"abstract":"An electric conductimetric sensor (thickness: 80 /spl mu/m) constructed in a sandwich configuration with a hydrophilic poly-tetrafluoroethylene membrane placed between two gold deposited layers was evaluated for use as a moisture sensor. The humidity level was measured by electrical conductivity of the device using the Multi-frequency LCR-meter at frequencies ranging from 100 Hz to 100 k Hz, the device was calibrated at 100 Hz against the moisture air over the range of 30-85 % RH, which includes normal humidity level in the atmosphere and physiologic air such as breath and sweating. The response sensitivity of the conductimetric device was extremely high (i.e. less than 1 sec. for conductivity shift between humid air of 80 % RH and dried air of -60 /spl deg/C dew point) even for recovery to dried air. The sensor performance was reproducible over multiple measurements, showing the highly reproducibility with a coefficient of variation of 1.77 % (n = 5).","PeriodicalId":129668,"journal":{"name":"2002 Conference on Optoelectronic and Microelectronic Materials and Devices. COMMAD 2002. Proceedings (Cat. No.02EX601)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2002 Conference on Optoelectronic and Microelectronic Materials and Devices. COMMAD 2002. Proceedings (Cat. No.02EX601)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/COMMAD.2002.1237231","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
An electric conductimetric sensor (thickness: 80 /spl mu/m) constructed in a sandwich configuration with a hydrophilic poly-tetrafluoroethylene membrane placed between two gold deposited layers was evaluated for use as a moisture sensor. The humidity level was measured by electrical conductivity of the device using the Multi-frequency LCR-meter at frequencies ranging from 100 Hz to 100 k Hz, the device was calibrated at 100 Hz against the moisture air over the range of 30-85 % RH, which includes normal humidity level in the atmosphere and physiologic air such as breath and sweating. The response sensitivity of the conductimetric device was extremely high (i.e. less than 1 sec. for conductivity shift between humid air of 80 % RH and dried air of -60 /spl deg/C dew point) even for recovery to dried air. The sensor performance was reproducible over multiple measurements, showing the highly reproducibility with a coefficient of variation of 1.77 % (n = 5).