Direct Template-Free Encryption Key Generation from Palm-Veins

K. Harmer, G. Howells
{"title":"Direct Template-Free Encryption Key Generation from Palm-Veins","authors":"K. Harmer, G. Howells","doi":"10.1109/EST.2012.20","DOIUrl":null,"url":null,"abstract":"In this paper, an investigation into the feasibility of applying the palm-vein biometric modality within a template-free key generation framework was conducted. In partnership with iCognize GmbH, experiments were conducted on both the raw images and the encoded biometric templates. Although feature analysis suggested difficulties may ensue due to the significant overlapping between genuine and impostor distributions, it was found that the framework still performed well for dataset of 20 subjects. The experiments resulted in both the key reproducibility and key uniqueness rates achieving 100% with considerable effective key lengths. These results are highly encouraging and demonstrate that stable keys can be achieved from poorly separable features.","PeriodicalId":314247,"journal":{"name":"2012 Third International Conference on Emerging Security Technologies","volume":"54 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 Third International Conference on Emerging Security Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EST.2012.20","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

In this paper, an investigation into the feasibility of applying the palm-vein biometric modality within a template-free key generation framework was conducted. In partnership with iCognize GmbH, experiments were conducted on both the raw images and the encoded biometric templates. Although feature analysis suggested difficulties may ensue due to the significant overlapping between genuine and impostor distributions, it was found that the framework still performed well for dataset of 20 subjects. The experiments resulted in both the key reproducibility and key uniqueness rates achieving 100% with considerable effective key lengths. These results are highly encouraging and demonstrate that stable keys can be achieved from poorly separable features.
直接模板无加密密钥从掌纹生成
本文研究了在无模板密钥生成框架中应用手掌静脉生物识别模式的可行性。与iCognize GmbH合作,对原始图像和编码的生物识别模板进行了实验。虽然特征分析表明,由于真实分布和冒名顶替分布之间的显著重叠,可能会出现困难,但发现该框架对于20个受试者的数据集仍然表现良好。实验结果表明,密钥可重复性和密钥唯一性率均达到100%,且有效密钥长度相当。这些结果是非常令人鼓舞的,并表明稳定的键可以从难以分离的特征中获得。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信