Elastic body splines: a physics based approach to coordinate transformation in medical image matching

M. Davis, A. Khotanzad, D. Flamig, S. Harms
{"title":"Elastic body splines: a physics based approach to coordinate transformation in medical image matching","authors":"M. Davis, A. Khotanzad, D. Flamig, S. Harms","doi":"10.1109/CBMS.1995.465443","DOIUrl":null,"url":null,"abstract":"In a landmark based medical image matching scheme, a coordinate transformation maps a set of landmark locations in one image onto a corresponding set in a second image. A novel approach to this transformation, the elastic body spline, is introduced. The development of the spline is outlined. An example of using the spline to match 3D magnetic resonance images (MRIs) of the breast is described. The elastic body spline is compared to the thin plate spline and, for 3D breast MRIs, is found to have superior performance as assessed by several measures of the similarity of the matched images.<<ETX>>","PeriodicalId":254366,"journal":{"name":"Proceedings Eighth IEEE Symposium on Computer-Based Medical Systems","volume":"306 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings Eighth IEEE Symposium on Computer-Based Medical Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CBMS.1995.465443","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 21

Abstract

In a landmark based medical image matching scheme, a coordinate transformation maps a set of landmark locations in one image onto a corresponding set in a second image. A novel approach to this transformation, the elastic body spline, is introduced. The development of the spline is outlined. An example of using the spline to match 3D magnetic resonance images (MRIs) of the breast is described. The elastic body spline is compared to the thin plate spline and, for 3D breast MRIs, is found to have superior performance as assessed by several measures of the similarity of the matched images.<>
弹性体样条:一种基于物理的医学图像匹配坐标变换方法
在基于地标的医学图像匹配方案中,坐标变换将一幅图像中的一组地标位置映射到另一幅图像中的相应集合上。本文介绍了一种新的变换方法——弹性体样条法。概述了样条的发展过程。描述了使用样条来匹配乳房的3D磁共振图像(mri)的一个示例。将弹性体样条与薄板样条进行比较,并通过对匹配图像的几种相似性进行评估,发现3D乳房mri具有优越的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信