{"title":"Intelligent power control system — A case study of the lighting power in communal lavatories","authors":"Jiaxiong Wen, Kuo-Ming Cheng","doi":"10.1109/ISRA.2012.6219292","DOIUrl":null,"url":null,"abstract":"In light of the demand for global greenhouse gas control proposed in Kyoto Protocol as well as promoting the efficiency of energy use, a power control system is proposed in this study. A lot of lighting power in communal lavatories is not managed and controlled that it is likely to be lit for 24 hours, once it is switched on. When there is no one using the lavatory but the lighting power is still on, abundant power waste is caused. If the number of people using the lavatory can be sensed and calculated as well as the lights can be automatically switched off when it is not in-use, the power could be economized for quality power management and waste preclusion. Moreover, if the data of power utilization could be transmitted to the server host and recorded in the database with remote connection, not only could the situation and the characteristics of power utilization be analyzed, but the switch time could also be intelligently self-regulated.","PeriodicalId":266930,"journal":{"name":"2012 IEEE Symposium on Robotics and Applications (ISRA)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE Symposium on Robotics and Applications (ISRA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISRA.2012.6219292","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In light of the demand for global greenhouse gas control proposed in Kyoto Protocol as well as promoting the efficiency of energy use, a power control system is proposed in this study. A lot of lighting power in communal lavatories is not managed and controlled that it is likely to be lit for 24 hours, once it is switched on. When there is no one using the lavatory but the lighting power is still on, abundant power waste is caused. If the number of people using the lavatory can be sensed and calculated as well as the lights can be automatically switched off when it is not in-use, the power could be economized for quality power management and waste preclusion. Moreover, if the data of power utilization could be transmitted to the server host and recorded in the database with remote connection, not only could the situation and the characteristics of power utilization be analyzed, but the switch time could also be intelligently self-regulated.
智能电源控制系统——以公共厕所照明电源为例
针对《京都议定书》提出的控制全球温室气体排放的要求,以及促进能源利用效率的要求,本研究提出了一种电力控制系统。许多公共厕所的照明电源没有管理和控制,一旦打开,它可能会亮24小时。在没有人使用厕所的情况下,照明电源仍然亮着,造成了大量的电力浪费。如果可以感应和计算使用厕所的人数,并且可以在不使用时自动关闭灯,则可以节省电力,进行优质电源管理和防止浪费。此外,如果能够将用电数据远程传输到服务器主机,并记录在数据库中,不仅可以分析用电情况和用电特点,还可以智能地自我调节开关时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信