Method of Averages to Determine Insulation Conductivity under Transient Conditions

E. Kossecka
{"title":"Method of Averages to Determine Insulation Conductivity under Transient Conditions","authors":"E. Kossecka","doi":"10.1177/109719639902300204","DOIUrl":null,"url":null,"abstract":"A simple method of data analysis, called the averaging technique, is presented which may be useful in long-term field measurements of temperature dependent thermal conductivity of insulating materials. Its mathematical basis is the integral statement, which follows from the heat conduction equation For lin ear dependence of conductivity on temperature, on neglecting capacity terms, it yields simple algorithms to determine thermal conductivity in transient heat flow, for the weighted average temperature, when the heat flux and surface temperatures are measured simultaneously, and also when the heat flux comparator method is em ployed. The problem of proper control of the temperature inside the exposure test box, in order to minimize the error due to neglecting capacity terms, is discussed.","PeriodicalId":435154,"journal":{"name":"Journal of Thermal Envelope and Building Science","volume":"88 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Thermal Envelope and Building Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/109719639902300204","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

A simple method of data analysis, called the averaging technique, is presented which may be useful in long-term field measurements of temperature dependent thermal conductivity of insulating materials. Its mathematical basis is the integral statement, which follows from the heat conduction equation For lin ear dependence of conductivity on temperature, on neglecting capacity terms, it yields simple algorithms to determine thermal conductivity in transient heat flow, for the weighted average temperature, when the heat flux and surface temperatures are measured simultaneously, and also when the heat flux comparator method is em ployed. The problem of proper control of the temperature inside the exposure test box, in order to minimize the error due to neglecting capacity terms, is discussed.
在瞬态条件下测定绝缘电导率的平均值法
提出了一种简单的数据分析方法,称为平均技术,它可以用于绝缘材料的温度相关导热系数的长期现场测量。对于导热系数与温度的线性关系,在忽略容量项的情况下,本文给出了计算瞬态热流中导热系数的简单算法,对于加权平均温度,同时测量热流密度和表面温度,以及采用热流密度比较器方法。讨论了适当控制暴露试验箱内温度的问题,以尽量减少因忽略容量项而造成的误差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信