A New Slot Type Axial Magnetic Field Contact with Low Resistance

Zhiyuan Liu, Z. Wang, Jimei Wang
{"title":"A New Slot Type Axial Magnetic Field Contact with Low Resistance","authors":"Zhiyuan Liu, Z. Wang, Jimei Wang","doi":"10.1109/DEIV.2006.357289","DOIUrl":null,"url":null,"abstract":"This paper introduces a new slot type axial magnetic field (AMF) contact. It has lower resistance compared with its counterpart conventional one by introducing a contact bridge that substitutes for stainless steel support in conventional contact. There is a gap between the contact bridge and contact plate. In close position, the contact bridge is pressed on contact plate by contact force and coil deformation. So current goes through the contact bridge to reach contact plate directly. In an interruption operation, the gap restores with contact force disappearing, which pushes current passing through coils of the slot type AMF contact. So the same AMF can be generated as a conventional one. As a result, short circuit current interruption tests showed that the interrupting capacity of the vacuum interrupter with new contacts was not less than that with conventional contacts. Resistance of vacuum interrupter with conventional contact is 10-12 muOmega at contact force 2000N. It decreased to 7muOmega with the new contact","PeriodicalId":369861,"journal":{"name":"2006 International Symposium on Discharges and Electrical Insulation in Vacuum","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 International Symposium on Discharges and Electrical Insulation in Vacuum","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DEIV.2006.357289","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

This paper introduces a new slot type axial magnetic field (AMF) contact. It has lower resistance compared with its counterpart conventional one by introducing a contact bridge that substitutes for stainless steel support in conventional contact. There is a gap between the contact bridge and contact plate. In close position, the contact bridge is pressed on contact plate by contact force and coil deformation. So current goes through the contact bridge to reach contact plate directly. In an interruption operation, the gap restores with contact force disappearing, which pushes current passing through coils of the slot type AMF contact. So the same AMF can be generated as a conventional one. As a result, short circuit current interruption tests showed that the interrupting capacity of the vacuum interrupter with new contacts was not less than that with conventional contacts. Resistance of vacuum interrupter with conventional contact is 10-12 muOmega at contact force 2000N. It decreased to 7muOmega with the new contact
一种新型低阻槽式轴向磁场接触器
介绍了一种新型槽型轴向磁场接触器。它通过引入接触桥来替代传统接触中的不锈钢支撑,与传统接触相比具有更低的电阻。接触桥和接触板之间有间隙。在闭合位置,接触桥是通过接触力和线圈变形压在接触板上。因此电流通过接触桥直接到达接触板。在中断操作中,随着接触力的消失,间隙恢复,从而推动电流通过槽型AMF触点的线圈。因此可以生成与传统AMF相同的AMF。因此,短路电流中断试验表明,采用新触点的真空灭弧器的中断能力不低于采用传统触点的真空灭弧器。在接触力为2000N时,常规触点真空灭弧电阻为10-12 μ ω。有了新的接触,它减小到7mu
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信