{"title":"Dynamics of the diesel-wind system with asynchronous generators","authors":"M. Babescu, C. Șorândaru, S. Musuroi, M. Svoboda","doi":"10.1109/SACI.2012.6250030","DOIUrl":null,"url":null,"abstract":"This paper proposes an original method of determining the maximum power function point of a wind turbine at variable wind speeds. There are presented the non-linear equations which model the wind turbine (WT), the diesel engine (DE) and the asynchronous generator (AG). The advantages of using the asynchronous versus synchronous generators are also outlined.","PeriodicalId":293436,"journal":{"name":"2012 7th IEEE International Symposium on Applied Computational Intelligence and Informatics (SACI)","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 7th IEEE International Symposium on Applied Computational Intelligence and Informatics (SACI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SACI.2012.6250030","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This paper proposes an original method of determining the maximum power function point of a wind turbine at variable wind speeds. There are presented the non-linear equations which model the wind turbine (WT), the diesel engine (DE) and the asynchronous generator (AG). The advantages of using the asynchronous versus synchronous generators are also outlined.