{"title":"Specific Features of the Replacement of the Available Flow Path by the Optimal Flow Path when Upgrading the Steam Turbine High-Pressure Cylinder","authors":"Riza Sherfedinov, Oleksandr Usatyi, O. Avdieieva, Mykhailo Daludin, Illia Yenin","doi":"10.20998/2078-774x.2021.04.01","DOIUrl":null,"url":null,"abstract":"This scientific paper gives the main research data obtained during the solution of the search problem to define optimal parameter values for the thermal circuit of the К-540-23.5 turbine unit that would provide the most efficient operation both for the optimal version of the high pressure cylinder (HPC) as part of the turbine unit and the turbine unit on the whole. The effect of the distribution of heat differences in the stages of the optimal flow part of the high pressure cylinder used by the К-540-23.5 turbine on the integral quality factors of the turbine unit has been assessed. The calculation studies of the thermal circuit of the turbine unit with the optimal flow section of the high-pressure cylinder showed that the temperature of the underheated feed water in the high pressure heater (HPH) arranged near the steam generator has the most critical effect on the power and economical efficiency of the high pressure cylinder and entire turbine unit. The two-criterion Pareto problem for the upgrading of the turbine unit was formulated and solved to define optimal underheating temperature values. Consideration was given to the two variants of the solution of the optimization problem for the feed water underheating temperature in the high pressure heater. Comparison and analysis of the two variants of solution for the two-criterion optimization problem showed the identity of the obtained data and it confirms the correctness of the problem formulation and the algorithms used for its solution.","PeriodicalId":416126,"journal":{"name":"NTU \"KhPI\" Bulletin: Power and heat engineering processes and equipment","volume":"83 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"NTU \"KhPI\" Bulletin: Power and heat engineering processes and equipment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20998/2078-774x.2021.04.01","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This scientific paper gives the main research data obtained during the solution of the search problem to define optimal parameter values for the thermal circuit of the К-540-23.5 turbine unit that would provide the most efficient operation both for the optimal version of the high pressure cylinder (HPC) as part of the turbine unit and the turbine unit on the whole. The effect of the distribution of heat differences in the stages of the optimal flow part of the high pressure cylinder used by the К-540-23.5 turbine on the integral quality factors of the turbine unit has been assessed. The calculation studies of the thermal circuit of the turbine unit with the optimal flow section of the high-pressure cylinder showed that the temperature of the underheated feed water in the high pressure heater (HPH) arranged near the steam generator has the most critical effect on the power and economical efficiency of the high pressure cylinder and entire turbine unit. The two-criterion Pareto problem for the upgrading of the turbine unit was formulated and solved to define optimal underheating temperature values. Consideration was given to the two variants of the solution of the optimization problem for the feed water underheating temperature in the high pressure heater. Comparison and analysis of the two variants of solution for the two-criterion optimization problem showed the identity of the obtained data and it confirms the correctness of the problem formulation and the algorithms used for its solution.
汽轮机高压缸升级时以最优流道替代可用流道的具体特点
本文给出了在求解搜索问题中获得的主要研究数据,以确定К-540-23.5汽轮机组热回路的最优参数值,从而为作为汽轮机组一部分的高压缸(HPC)的最佳版本和整体汽轮机组提供最有效的运行。研究了К-540-23.5汽轮机高压缸最优流动部分各级热差分布对机组整体质量因子的影响。对高压缸最佳流段汽轮机组热回路的计算研究表明,布置在蒸汽发生器附近的高压加热器(HPH)内的欠热给水温度对高压缸和整个汽轮机组的功率和经济性影响最为关键。建立并求解了汽轮机组升级改造的双准则Pareto问题,以确定机组最优过热值。考虑了高压加热器给水欠加热温度优化问题的两种解。通过对双准则优化问题的两种解的比较分析,表明所得到的数据是一致的,证实了问题表述和求解算法的正确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信