{"title":"Compensation for two specific types of artifact in pulse wave using a Kalman filter","authors":"M. Yarita, N. Kobayashi, S. Takeda, Toshiyo Tamura","doi":"10.1109/ITAB.2007.4407399","DOIUrl":null,"url":null,"abstract":"An algorithm is proposed to interpolate the pulse wave during the measurement of SpO2 by using Kalman filter identification of autoregression (AR) coefficients, Kalman filter interpolation, and a fixed-interval smoother. This combined algorithm picks up the pulse rate smoothly from pulse waves contaminated by two specific artifact types: respiration artifact and sporadic body movement artifact.","PeriodicalId":129874,"journal":{"name":"2007 6th International Special Topic Conference on Information Technology Applications in Biomedicine","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 6th International Special Topic Conference on Information Technology Applications in Biomedicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ITAB.2007.4407399","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

An algorithm is proposed to interpolate the pulse wave during the measurement of SpO2 by using Kalman filter identification of autoregression (AR) coefficients, Kalman filter interpolation, and a fixed-interval smoother. This combined algorithm picks up the pulse rate smoothly from pulse waves contaminated by two specific artifact types: respiration artifact and sporadic body movement artifact.
用卡尔曼滤波器补偿脉冲波中两种特定类型的伪影
提出了一种利用卡尔曼滤波识别自回归(AR)系数、卡尔曼滤波插值和定间隔平滑对SpO2测量过程中的脉冲波进行插值的算法。该算法从两种特定的伪影(呼吸伪影和零星的身体运动伪影)污染的脉搏波中平滑地提取出脉搏率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信