{"title":"A sensitivity analysis based security constrained optimal power flow for allocation of reactive capability in a competitive environment","authors":"L. Yao, G. Strbac","doi":"10.1109/PTC.1999.826492","DOIUrl":null,"url":null,"abstract":"This paper presents a sensitivity analysis based security constrained optimal power flow (SCOPF) for solving the green field VAr allocation problem. Sensitivity analysis is used to quantify the impact of an incremental change in reactive pattern and various controls on the voltage profiles for a number of power system states. An efficient method for computing all relevant sensitivities is developed for that purpose and incorporated within the LP based SCOPF. The proposed scheme is implemented to optimally allocate reactive power reserves among system generators. Results of the case studies carried out on the IEEE-30 bus system demonstrate the validity of the developed sensitivity analysis based SCOPF method.","PeriodicalId":101688,"journal":{"name":"PowerTech Budapest 99. Abstract Records. (Cat. No.99EX376)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"PowerTech Budapest 99. Abstract Records. (Cat. No.99EX376)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PTC.1999.826492","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

This paper presents a sensitivity analysis based security constrained optimal power flow (SCOPF) for solving the green field VAr allocation problem. Sensitivity analysis is used to quantify the impact of an incremental change in reactive pattern and various controls on the voltage profiles for a number of power system states. An efficient method for computing all relevant sensitivities is developed for that purpose and incorporated within the LP based SCOPF. The proposed scheme is implemented to optimally allocate reactive power reserves among system generators. Results of the case studies carried out on the IEEE-30 bus system demonstrate the validity of the developed sensitivity analysis based SCOPF method.
基于灵敏度分析的竞争环境下无功容量分配安全约束最优潮流
本文提出了一种基于灵敏度分析的安全约束最优潮流(SCOPF)方法来解决绿地无功值分配问题。灵敏度分析用于量化无功模式的增量变化和各种控制对许多电力系统状态的电压分布的影响。为此目的开发了一种计算所有相关灵敏度的有效方法,并将其纳入基于LP的SCOPF中。该方案实现了系统各发电机组间无功储备的优化分配。在IEEE-30总线系统上进行的实例研究结果证明了基于SCOPF方法的灵敏度分析的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信