Suggested Design Guidelines for Seismic Retrofit with SIMCON and SIFCON

E. Dogan, H. Hill, N. Krstulovic-Opara
{"title":"Suggested Design Guidelines for Seismic Retrofit with SIMCON and SIFCON","authors":"E. Dogan, H. Hill, N. Krstulovic-Opara","doi":"10.14359/5717","DOIUrl":null,"url":null,"abstract":"This paper suggests design guidelines for seismic retrofit of nonseismically designed reinforced concrete frames using high performance fiber reinforced concretes (HPFRCs) such as slurry infiltrated mat concrete (SIMCON) and slurry infiltrated fiber concrete (SIFCON). The following retrofit schemes are addressed: column retrofit with either discontinuous or continuous SIMCON jackets and joint retrofit by either internal retrofit with prestressing bars or external SIMCON jacketing.","PeriodicalId":148554,"journal":{"name":"SP-185: High-Performance Fiber Reinforced Concrete in Infrastructural Repair and Retrofit","volume":"57 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SP-185: High-Performance Fiber Reinforced Concrete in Infrastructural Repair and Retrofit","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14359/5717","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

This paper suggests design guidelines for seismic retrofit of nonseismically designed reinforced concrete frames using high performance fiber reinforced concretes (HPFRCs) such as slurry infiltrated mat concrete (SIMCON) and slurry infiltrated fiber concrete (SIFCON). The following retrofit schemes are addressed: column retrofit with either discontinuous or continuous SIMCON jackets and joint retrofit by either internal retrofit with prestressing bars or external SIMCON jacketing.
采用SIMCON和SIFCON进行抗震加固的建议设计指引
本文提出了采用高性能纤维增强混凝土(HPFRCs)(如浆液渗透垫层混凝土(SIMCON)和浆液渗透纤维混凝土(SIFCON))对非抗震设计的钢筋混凝土框架进行抗震改造的设计指南。本文讨论了以下改造方案:采用不连续或连续的SIMCON护套对柱进行改造,以及采用预应力杆或外部SIMCON护套进行内部改造的接头改造。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信