A new look at the PPAC

E. Norbeck, J. Olson, Y. Onel
{"title":"A new look at the PPAC","authors":"E. Norbeck, J. Olson, Y. Onel","doi":"10.1556/APH.25.2006.2-4.38","DOIUrl":null,"url":null,"abstract":"The Parallel Plate Avalanche Counter (PPAC) has been used mostly for measuring the energy loss of single, heavily ionizing particles. A PPAC is even more effective with high-energy showers for which a single event causes hundreds of electrons to pass through it. For operation at reduced pressures, the alkanes such as isobutane, C4H10 are excellent PPAC gasses with the quality of performance increasing with the size of the molecule. Under some circumstances the perfluoroalkanes such as perfluoropropane, C3F8, may be preferred. For operation at atmospheric pressure, CF4 and mixtures containing Ar and CO2 work well.","PeriodicalId":201208,"journal":{"name":"Acta Physica Hungarica A) Heavy Ion Physics","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Physica Hungarica A) Heavy Ion Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1556/APH.25.2006.2-4.38","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The Parallel Plate Avalanche Counter (PPAC) has been used mostly for measuring the energy loss of single, heavily ionizing particles. A PPAC is even more effective with high-energy showers for which a single event causes hundreds of electrons to pass through it. For operation at reduced pressures, the alkanes such as isobutane, C4H10 are excellent PPAC gasses with the quality of performance increasing with the size of the molecule. Under some circumstances the perfluoroalkanes such as perfluoropropane, C3F8, may be preferred. For operation at atmospheric pressure, CF4 and mixtures containing Ar and CO2 work well.
PPAC的新面貌
平行板雪崩计数器(PPAC)主要用于测量单个重电离粒子的能量损失。PPAC在高能阵雨中更有效,因为一个事件会导致数百个电子穿过它。对于减压操作,异丁烷、C4H10等烷烃是优良的PPAC气体,其性能质量随分子尺寸的增大而提高。在某些情况下,可优选全氟烷烃,如全氟丙烷C3F8。对于常压下的操作,CF4和含有Ar和CO2的混合物工作良好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信