{"title":"Improvement of the CERN SPS electrostatic septa ion traps","authors":"B. Balhan, R. Barlow, J. Borburgh, G. Raffaele","doi":"10.1109/DEIV.2016.7764034","DOIUrl":null,"url":null,"abstract":"At CERN, the SPS synchrotron is equipped with a slow extraction channel towards the fixed target beam lines in the North Area This channel includes five consecutive electrostatic septa, where the field free region and the active high field region are separated by an array of tungsten-rhenium wires. The field-free region provides for the circulating beam, while the high field region is used to deflect the extracted beam. Since the residual gas can be ionized by the orbiting beam, low energy ions could cross the wire array and enter the high field region and cause high voltage breakdown when accelerated onto the cathode. To prevent low energy ions from entering this high electric field region, a vertical field is applied to the orbiting beam using so-called `ion traps' for active protection. The vertical field is created by electrodes placed inside the region containing the circulating beam. Due to electromagnetic coupling onto the ion trap electrodes observed with the high frequency LHC beam (25 ns spaced bunches), the efficiency of the ion traps is greatly reduced. This leads to increased vacuum activity (electron cloud related) as well as high spark rates both in the main field and between the ion trap electrodes and their grounded support. In view of the SPS performance increase required for HL-LHC, this paper highlights the upgrades and improvements required to obtain a stable ion trap field and significantly reduce the number of breakdown events observed with the LHC beam in the accelerator.","PeriodicalId":296641,"journal":{"name":"2016 27th International Symposium on Discharges and Electrical Insulation in Vacuum (ISDEIV)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 27th International Symposium on Discharges and Electrical Insulation in Vacuum (ISDEIV)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DEIV.2016.7764034","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

At CERN, the SPS synchrotron is equipped with a slow extraction channel towards the fixed target beam lines in the North Area This channel includes five consecutive electrostatic septa, where the field free region and the active high field region are separated by an array of tungsten-rhenium wires. The field-free region provides for the circulating beam, while the high field region is used to deflect the extracted beam. Since the residual gas can be ionized by the orbiting beam, low energy ions could cross the wire array and enter the high field region and cause high voltage breakdown when accelerated onto the cathode. To prevent low energy ions from entering this high electric field region, a vertical field is applied to the orbiting beam using so-called `ion traps' for active protection. The vertical field is created by electrodes placed inside the region containing the circulating beam. Due to electromagnetic coupling onto the ion trap electrodes observed with the high frequency LHC beam (25 ns spaced bunches), the efficiency of the ion traps is greatly reduced. This leads to increased vacuum activity (electron cloud related) as well as high spark rates both in the main field and between the ion trap electrodes and their grounded support. In view of the SPS performance increase required for HL-LHC, this paper highlights the upgrades and improvements required to obtain a stable ion trap field and significantly reduce the number of breakdown events observed with the LHC beam in the accelerator.
CERN SPS静电隔离阱的改进
在欧洲核子研究中心,SPS同步加速器配备了一条通往北区固定目标波束线的慢速提取通道,该通道包括五个连续的静电间隔,其中自由场区和活跃高场区由一组钨铼线隔开。无场区提供循环光束,而高场区用于偏转提取光束。由于残余气体可以被轨道束电离,低能离子可以穿过导线阵列进入高场区,加速到阴极上造成高压击穿。为了防止低能量离子进入这个高电场区域,使用所谓的“离子陷阱”对轨道光束施加垂直场以进行主动保护。垂直场是由放置在包含循环光束的区域内的电极产生的。由于离子阱电极与高频LHC束流(间隔25 ns束)的电磁耦合,离子阱的效率大大降低。这会导致真空活度(电子云相关)的增加,以及主场和离子阱电极及其接地支架之间的高火花率。鉴于HL-LHC需要提高SPS性能,本文重点介绍了获得稳定离子阱场和显著减少LHC束流在加速器中观察到的击穿事件数量所需的升级和改进。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信