Application of modified wavelet packet transform for de-noising during partial discharge measurement on power cables

M. Jayakrishnan, B. N. Rao
{"title":"Application of modified wavelet packet transform for de-noising during partial discharge measurement on power cables","authors":"M. Jayakrishnan, B. N. Rao","doi":"10.1109/CATCON.2017.8280223","DOIUrl":null,"url":null,"abstract":"PD monitoring is an effective tool for evaluating the insulation condition of high voltage equipment. However, the major challenge during on site PD measurement is that PD signals are severely affected by external noises and disturbances like white noise, random noise, Discrete Spectral Interferences (DSI), which are generated due to broadcasting stations, stochastic noise and pulses from power electronics at site conditions. Extracting PD signals from these noises is a challenging task. A method for de-noising PD signals using a modified version of Wavelet Packet Transform (WPT) proposed earlier [1] is refined further to improve its de-noising performance. In this paper, the application of Modified Wavelet Packet Transform for de-noising partial discharge signals in power cables has been carried out. The results are presented and discussed.","PeriodicalId":250717,"journal":{"name":"2017 3rd International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"65 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 3rd International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CATCON.2017.8280223","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

PD monitoring is an effective tool for evaluating the insulation condition of high voltage equipment. However, the major challenge during on site PD measurement is that PD signals are severely affected by external noises and disturbances like white noise, random noise, Discrete Spectral Interferences (DSI), which are generated due to broadcasting stations, stochastic noise and pulses from power electronics at site conditions. Extracting PD signals from these noises is a challenging task. A method for de-noising PD signals using a modified version of Wavelet Packet Transform (WPT) proposed earlier [1] is refined further to improve its de-noising performance. In this paper, the application of Modified Wavelet Packet Transform for de-noising partial discharge signals in power cables has been carried out. The results are presented and discussed.
改进小波包变换在电力电缆局部放电测量中的降噪应用
局部放电监测是评估高压设备绝缘状况的有效手段。然而,现场PD测量的主要挑战是PD信号受到外部噪声和干扰的严重影响,如白噪声、随机噪声、离散频谱干扰(DSI),这些干扰是由广播电台、现场条件下电力电子设备产生的随机噪声和脉冲产生的。从这些噪声中提取PD信号是一项具有挑战性的任务。本文进一步改进了先前[1]提出的一种改进的小波包变换(WPT)对PD信号去噪的方法,以提高其去噪性能。本文研究了改进小波包变换在电力电缆局部放电信号降噪中的应用。给出了实验结果并进行了讨论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信