{"title":"Auxiliaries for high-voltage D-C. multiple unit cars","authors":"C. Axtell","doi":"10.1109/T-AIEE.1930.5055658","DOIUrl":null,"url":null,"abstract":"The selection and application of auxiliary electrical devices on a high-voltage multiple unit car is of almost as much importance as the application of the main traction apparatus and requires careful consideration. This paper contains a description of the engineering features as worked out for electrified suburban lines operating on 1500-volt and 3000-volt systems. The control circuits have become very generally standardized at 32-volts, which is also well adapted for interior illumination and headlights. A motor driven generator supplies 3- to 5-kw. power per unit for control lights and battery charging. Such devices as heaters and motor-generator sets, requiring a considerable amount of electrical power, are necessarily constructed to operate at trolley potential. On the 1500-volt system, the compressor can be operated directly from the line potential while on the 3000-volt systems, a double commutator motor driving the generator supplies a 1500-volt source of power for the compressor.","PeriodicalId":260406,"journal":{"name":"Journal of the A.I.E.E.","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1930-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the A.I.E.E.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/T-AIEE.1930.5055658","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The selection and application of auxiliary electrical devices on a high-voltage multiple unit car is of almost as much importance as the application of the main traction apparatus and requires careful consideration. This paper contains a description of the engineering features as worked out for electrified suburban lines operating on 1500-volt and 3000-volt systems. The control circuits have become very generally standardized at 32-volts, which is also well adapted for interior illumination and headlights. A motor driven generator supplies 3- to 5-kw. power per unit for control lights and battery charging. Such devices as heaters and motor-generator sets, requiring a considerable amount of electrical power, are necessarily constructed to operate at trolley potential. On the 1500-volt system, the compressor can be operated directly from the line potential while on the 3000-volt systems, a double commutator motor driving the generator supplies a 1500-volt source of power for the compressor.