{"title":"Magnetic microsystem with extended dynamic range and absolute accuracy","authors":"A. Sešek, J. Trontelj","doi":"10.1109/ICECS.2008.4674995","DOIUrl":null,"url":null,"abstract":"A new concept of magnetic microsystem design is proposed to increase the dynamic range and absolute accuracy. The measured result on the realized microsystem of the noise density is better than 80 nT/radic(Hz) in frequency range from DC to 10 kHz. The absolute accuracy is obtained by integrated continuous autocalibration.","PeriodicalId":404629,"journal":{"name":"2008 15th IEEE International Conference on Electronics, Circuits and Systems","volume":"92 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-11-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 15th IEEE International Conference on Electronics, Circuits and Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICECS.2008.4674995","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
A new concept of magnetic microsystem design is proposed to increase the dynamic range and absolute accuracy. The measured result on the realized microsystem of the noise density is better than 80 nT/radic(Hz) in frequency range from DC to 10 kHz. The absolute accuracy is obtained by integrated continuous autocalibration.