{"title":"A computer-based bioelectrical impedance spectroscopic system for noninvasive assessment of compartmental fluid redistribution","authors":"W. Gerth, L. Montgomery, Yi-Chang Wu","doi":"10.1109/CBMSYS.1990.109432","DOIUrl":null,"url":null,"abstract":"Bioimpedance methods using fixed frequency stimulation to measure volume changes and hemodynamic parameters in body segments of human subjects under various conditions of body position and orthostatic stress are discussed. An electrical impedance spectroscopic (EIS) system has been developed to allow extension of these studies to include examination of the redistribution of fluids between the intracellular and extracellular compartments of the monitored body segments. Evaluated in studies of the human calf and thigh during 90 min of 6 degrees or 10 degrees head-down bed rest, the system promises to enable tracking of segmental and compartmental fluid redistribution in response to various environmental and physiological stresses with both temporal and anatomic resolution greater than that attainable with other methods.<<ETX>>","PeriodicalId":365366,"journal":{"name":"[1990] Proceedings. Third Annual IEEE Symposium on Computer-Based Medical Systems","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1990-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"[1990] Proceedings. Third Annual IEEE Symposium on Computer-Based Medical Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CBMSYS.1990.109432","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

Abstract

Bioimpedance methods using fixed frequency stimulation to measure volume changes and hemodynamic parameters in body segments of human subjects under various conditions of body position and orthostatic stress are discussed. An electrical impedance spectroscopic (EIS) system has been developed to allow extension of these studies to include examination of the redistribution of fluids between the intracellular and extracellular compartments of the monitored body segments. Evaluated in studies of the human calf and thigh during 90 min of 6 degrees or 10 degrees head-down bed rest, the system promises to enable tracking of segmental and compartmental fluid redistribution in response to various environmental and physiological stresses with both temporal and anatomic resolution greater than that attainable with other methods.<>
一种基于计算机的生物电阻抗光谱系统,用于无创评估室间流体再分配
讨论了利用固定频率刺激测量人体在不同体位和体位压力条件下的体积变化和血流动力学参数的生物阻抗方法。开发了电阻抗光谱(EIS)系统,以允许扩展这些研究,包括检查被监测身体节段的细胞内和细胞外隔室之间流体的再分配。在6度或10度头朝下卧床休息90分钟的人体小腿和大腿的研究中,该系统有望在各种环境和生理压力下跟踪节段和隔室液体再分配,其时间和解剖分辨率都比其他方法更高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信