{"title":"A new method for false-positive reduction in detection of lung nodules in CT images","authors":"Guo Cao, Yazhou Liu, Kenji Suzuki","doi":"10.1109/ICDSP.2014.6900710","DOIUrl":null,"url":null,"abstract":"This paper proposes a novel approach for false-positive reduction in lung nodule detection based on structure relationship analysis between nodule candidate and vessel, and the modified surface normal overlap descriptor. On one hand, a large number of false nodules attached to vessels can be removed by analyzing the relationship between nodule candidates and their attached tissues. On the other hand, Low-contrast nonsolid nodules are discriminated from the candidates with modified surface normal overlap descriptor. The proposed method has been trained and validated on a clinical dataset of 90 thoracic CT scans using a low dose levels that contain 90 nodules (62 solid nodules, 25 ground-glass opacity nodules and 3 mixed nodules) determined by a ground truth reading process.","PeriodicalId":301856,"journal":{"name":"2014 19th International Conference on Digital Signal Processing","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 19th International Conference on Digital Signal Processing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICDSP.2014.6900710","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
This paper proposes a novel approach for false-positive reduction in lung nodule detection based on structure relationship analysis between nodule candidate and vessel, and the modified surface normal overlap descriptor. On one hand, a large number of false nodules attached to vessels can be removed by analyzing the relationship between nodule candidates and their attached tissues. On the other hand, Low-contrast nonsolid nodules are discriminated from the candidates with modified surface normal overlap descriptor. The proposed method has been trained and validated on a clinical dataset of 90 thoracic CT scans using a low dose levels that contain 90 nodules (62 solid nodules, 25 ground-glass opacity nodules and 3 mixed nodules) determined by a ground truth reading process.