{"title":"A power losses calculation in a four-legged three-level voltage source inverter","authors":"M. Dybko, S. S. Turnaev, S. Brovanov","doi":"10.1109/EDM.2009.5174013","DOIUrl":null,"url":null,"abstract":"This paper presents analytical equations for power losses calculation in three-level VSI controlled by carrier-based PWM with third harmonic injection. A magnitude current value in the four leg devices depending on three-phase load unbalance was obtained.","PeriodicalId":262499,"journal":{"name":"2009 International Conference and Seminar on Micro/Nanotechnologies and Electron Devices","volume":"80 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 International Conference and Seminar on Micro/Nanotechnologies and Electron Devices","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EDM.2009.5174013","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8
Abstract
This paper presents analytical equations for power losses calculation in three-level VSI controlled by carrier-based PWM with third harmonic injection. A magnitude current value in the four leg devices depending on three-phase load unbalance was obtained.