The numerical evaluations on SAR around an implanted cardiac pacemaker by a mobile phone of multiple operating frequencies

K. Saito, R. Akiyama, T. Nagaoka, Soichi Watanabe
{"title":"The numerical evaluations on SAR around an implanted cardiac pacemaker by a mobile phone of multiple operating frequencies","authors":"K. Saito, R. Akiyama, T. Nagaoka, Soichi Watanabe","doi":"10.1109/IWAT.2017.7915344","DOIUrl":null,"url":null,"abstract":"In recent years, electromagnetic interference (EMI) of an implanted cardiac pacemaker (PM) has been investigated. However, there are few studies of specific absorption rate (SAR) around the PM by the mobile radio terminal. In this paper, SAR due to a wireless radio terminal which has high resolution source model is calculated. As a result of calculations, SAR at 2 GHz was 4 times higher than that at 900 MHz because of reflection wave at PM housing. However, all calculated SARs were below the international safety guidelines.","PeriodicalId":289886,"journal":{"name":"2017 International Workshop on Antenna Technology: Small Antennas, Innovative Structures, and Applications (iWAT)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 International Workshop on Antenna Technology: Small Antennas, Innovative Structures, and Applications (iWAT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IWAT.2017.7915344","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In recent years, electromagnetic interference (EMI) of an implanted cardiac pacemaker (PM) has been investigated. However, there are few studies of specific absorption rate (SAR) around the PM by the mobile radio terminal. In this paper, SAR due to a wireless radio terminal which has high resolution source model is calculated. As a result of calculations, SAR at 2 GHz was 4 times higher than that at 900 MHz because of reflection wave at PM housing. However, all calculated SARs were below the international safety guidelines.
多工作频率手机对植入式心脏起搏器周围SAR的数值评价
近年来,人们对植入式心脏起搏器(PM)的电磁干扰进行了研究。然而,移动无线电终端在PM附近的比吸收率(SAR)的研究很少。本文对具有高分辨率源模型的无线无线电终端的SAR进行了计算。计算结果表明,由于PM壳体反射波的影响,2ghz时的SAR比900mhz时高4倍。然而,所有计算出的SARs都低于国际安全准则。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信