High-resolution local imaging using a micro-CT

S. Lee, M. Cho, J. Choi
{"title":"High-resolution local imaging using a micro-CT","authors":"S. Lee, M. Cho, J. Choi","doi":"10.1109/ISBI.2008.4540951","DOIUrl":null,"url":null,"abstract":"An X-ray micro-tomography system has been developed for in vivo small animal imaging studies. For efficient in vivo scanning, it has a rotating gantry on which the X-ray source and the flat panel X-ray detector are mounted. To reconstruct artifact-free images of a small local region inside the animal subject from the truncated projection data, the projection data from the large field of view (FOV) scan of the whole animal subject are combined with the projection data from the small FOV scan of the region of interest. For the acquisition of X-ray projection data, a 1248 times 1248 flat-panel x-ray detector with the pixel pitch of 100 mum has been used. The developed system has the spatial resolution of 12 lp/mm when the highest magnification ratio of 5:1 is applied to the zoom-in imaging.","PeriodicalId":184204,"journal":{"name":"2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-05-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISBI.2008.4540951","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

An X-ray micro-tomography system has been developed for in vivo small animal imaging studies. For efficient in vivo scanning, it has a rotating gantry on which the X-ray source and the flat panel X-ray detector are mounted. To reconstruct artifact-free images of a small local region inside the animal subject from the truncated projection data, the projection data from the large field of view (FOV) scan of the whole animal subject are combined with the projection data from the small FOV scan of the region of interest. For the acquisition of X-ray projection data, a 1248 times 1248 flat-panel x-ray detector with the pixel pitch of 100 mum has been used. The developed system has the spatial resolution of 12 lp/mm when the highest magnification ratio of 5:1 is applied to the zoom-in imaging.
使用微型ct进行高分辨率局部成像
研制了一种用于小动物体内成像研究的x射线微断层扫描系统。为了有效地在体内扫描,它有一个旋转的龙门架,x射线源和平板x射线探测器安装在上面。为了从截断的投影数据中重建动物主体内部小区域的无伪影图像,将整个动物主体的大视场扫描的投影数据与感兴趣区域的小视场扫描的投影数据相结合。x射线投影数据采集采用1248 × 1248平板x射线探测器,像素间距为100 μ m。在最大放大倍率为5:1时,系统的空间分辨率可达12 lp/mm。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信