Response calibration for automated network analyzer systems

W. Zheng, C.E. Smith, L. Wang
{"title":"Response calibration for automated network analyzer systems","authors":"W. Zheng, C.E. Smith, L. Wang","doi":"10.1109/SSST.1993.522736","DOIUrl":null,"url":null,"abstract":"An automated response calibration for the Hewlett-Packard Model HP8410 network analyzer system is studied. Response calibration is based on correction of frequency response magnitude and phase system errors. This measurements approach is much faster than the normal VNA 8-term error model because only one standard is required for calibration. System accuracy is comparable to other automated network analyzers. A data acquisition program has been developed to implement response calibration of the HP8410 in order to extend the long-term use of this unit.","PeriodicalId":260036,"journal":{"name":"1993 (25th) Southeastern Symposium on System Theory","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1993 (25th) Southeastern Symposium on System Theory","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SSST.1993.522736","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

An automated response calibration for the Hewlett-Packard Model HP8410 network analyzer system is studied. Response calibration is based on correction of frequency response magnitude and phase system errors. This measurements approach is much faster than the normal VNA 8-term error model because only one standard is required for calibration. System accuracy is comparable to other automated network analyzers. A data acquisition program has been developed to implement response calibration of the HP8410 in order to extend the long-term use of this unit.
自动网络分析系统的响应校准
研究了HP8410型网络分析仪系统的自动响应校准方法。响应校准是基于频率响应幅度和相位系统误差的校正。这种测量方法比正常的VNA 8项误差模型要快得多,因为校准只需要一个标准。系统精度可与其他自动化网络分析仪相媲美。为了延长该装置的长期使用,开发了一种数据采集程序来实现HP8410的响应校准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信